Skip to content
Use caution Medical device recall · FDA · Published July 17, 2017

RayStation 6 Software Recall: Incorrect Radiation Dose Risk

RaySearch Laboratories recalls RayStation 6 software versions 6.0.0.24, 6.1.0.26, 6.1.1.2, and 6.2.0.7 due to potential incorrect radiation dose calculations during proton therapy QA checks.

🇺🇸 FDA recall #Z-0380-2018Medical deviceRaySearch Laboratories ›
Take action

Contact the company

Recalling firmRAYSEARCH LABORATORIES ABSveavaegen 9 · Stockholm, Sweden
✎ GovInfoNow plain-language explainer

What happened, in plain English

RaySearch Laboratories is recalling specific versions of their RayStation 6 software used in radiation therapy treatment planning. The software may calculate incorrect radiation doses for patients if the snout position or gap settings are modified in the quality assurance module, which could lead to unsafe treatment outcomes. Read more at govinfonow.com/recall/73407-raystation-6-software-recall-incorrect-radiation-dose-risk.

Source Summary by GovInfoNow · govinfonow.com/recall/73407-raystation-6-software-recall-incorrect-radiation-dose-risk · Updated September 20, 2026 · FDA enforcement record: FDA #Z-0380-2018

Cite this page

“RayStation 6 Software Recall: Incorrect Radiation Dose Risk.” GovInfoNow, updated September 20, 2026. https://govinfonow.com/recall/73407-raystation-6-software-recall-incorrect-radiation-dose-risk. Based on FDA recall #Z-0380-2018 (https://api.fda.gov/device/enforcement.json?search=recall_number:%22Z-0380-2018%22&limit=1).

Why it’s dangerous

If the snout position or gap settings are changed in the quality assurance module of RayStation 6, the software may compute radiation doses for a different treatment setup than what was actually used for measurements. This could result in patients receiving an incorrect radiation dose during their treatment.

Who’s affected

Healthcare professionals using RayStation 6 software for proton therapy treatment planning are most at risk. Patients receiving radiation therapy using these specific software versions could be affected if the software calculates incorrect doses.

How to tell if you have this one

Check if you have RayStation 6 software versions 6.0.0.24, 6.1.0.26, 6.1.1.2, or 6.2.0.7. These versions are used for proton therapy treatment planning and analysis in radiation therapy.

  • Brand
    RaySearch Laboratories
  • Category
    Medical device
Based on the official FDA remedy

What to do — step by step

  1. Check Software Version

    Identify your RayStation 6 version by checking the software's version number in the application settings.

  2. Update Software

    Update to a newer version of RayStation 6 that is not listed in the recall to avoid the risk of incorrect dose calculations.

Where it went and when

Where it was distributed

Distributed nationwide; the notice names 7 states.

Alaska: nationwideAKMaine: nationwideMEVermont: nationwideVTNew Hampshire: nationwideNHWashington: named in the noticeWAIdaho: nationwideIDMontana: nationwideMTNorth Dakota: nationwideNDMinnesota: nationwideMNIllinois: nationwideILWisconsin: nationwideWIMichigan: named in the noticeMINew York: nationwideNYRhode Island: nationwideRIMassachusetts: nationwideMAOregon: nationwideORNevada: nationwideNVWyoming: nationwideWYSouth Dakota: nationwideSDIowa: nationwideIAIndiana: nationwideINOhio: nationwideOHPennsylvania: nationwidePANew Jersey: nationwideNJConnecticut: nationwideCTCalifornia: nationwideCAUtah: nationwideUTColorado: nationwideCONebraska: nationwideNEMissouri: nationwideMOKentucky: nationwideKYWest Virginia: nationwideWVVirginia: nationwideVAMaryland: named in the noticeMDDelaware: nationwideDEArizona: named in the noticeAZNew Mexico: nationwideNMKansas: nationwideKSArkansas: nationwideARTennessee: named in the noticeTNNorth Carolina: nationwideNCSouth Carolina: nationwideSCDistrict of Columbia: named in the noticeDCOklahoma: nationwideOKLouisiana: nationwideLAMississippi: nationwideMSAlabama: nationwideALGeorgia: nationwideGAHawaii: nationwideHITexas: named in the noticeTXFlorida: named in the noticeFL

FDA distribution: “US Nationwide Distribution - FL, WA, AZ, TN, MD, TX, FL, MI, Washington D.C.” States read from FDA’s own wording; “not listed” means the notice does not name it.

Named in the notice: Arizona, District of Columbia, Florida, Maryland, Michigan, Tennessee, Texas, Washington.

Recall timeline

FDA terminated this recall 13 months after the firm started it.

1. Firm started the recall: Jul 17, 201712. FDA classified it Class II: Jan 16, 201823. Published in FDA’s Enforcement Report: Jan 24, 201834. FDA terminated the recall: Aug 29, 2018420172018
  1. Firm started the recall
  2. FDA classified it Class II
  3. Published in FDA’s Enforcement Report
  4. FDA terminated the recall

Dates from the agency record only; steps without a date are left out.

Similar recalls

Latest medical device recalls

Keep exploring

Where this comes from

The facts (hazard, remedy, dates, manufacturer) are pulled from the official FDA recall record. The plain-language summary and step-by-step checklist are written by GovInfoNow to make the official notice easier to act on — they don’t replace it.

  • Official source: FDA Recall #Z-0380-2018 (July 17, 2017) — FDA publishes no per-recall page; this is the official machine-readable enforcement record. Search FDA recalls for Z-0380-2018 to see it in context.
  • Plain-language summary written by qwen3:4b on September 20, 2026, from the official record above. Not reviewed by a person — if it conflicts with the FDA notice, the notice is correct. Report an error on this page.
  • GovInfoNow is an independent service and is not a government agency. We republish official FDA recall data; we don’t issue, amend or administer recalls.
GovInfoNow is an independent guide. We are not FDA or any government agency. Always confirm details with the official recall.Data: CPSC · FDA · NHTSA · USDA