Every recall we track for Hamilton Medical AG — 14 in all — plus the complaints and injury reports the public filed about them.
Hamilton Medical recalls coaxial breathing circuit sets (REFs 260127-260168) used with C1/T1/MR1 ventilators. Membranes may stick to valves, causing exhalation obstruction and oxygen desaturation if not tested before use.
Hamilton Medical recalls IntelliCuff portable blood pressure cuffs with REF 951001 due to potential "Cuff System Leakage" error causing continuous motor operation and pressure failure.
Hamilton Medical recalls breathing circuits with possible blue tubing cracks that could cause rebreathing of exhaled gases, leading to respiratory issues. Affected units include specific model numbers and serial lots.
Hamilton Medical recalls C6 ventilators with specific serial numbers due to a PCB defect that can cause ventilation failure. Affected units may stop working during use, risking interrupted breathing support.
Hamilton Medical recalls HAMILTON-C6 ventilators with specific software versions due to potential hypoxia if sensor fail mode occurs after patient reconnection. Affected units have UDI 07630002808590 and software versions v1.1.4 to v1.1.6.
Hamilton Medical recalls C6 ventilators with software version 1.2.1 due to safety ventilation mode not monitoring patient inputs, risking undetected issues during certain settings.
Hamilton Medical recalls C6 ventilators with serial numbers starting 6093-9590 due to temporary screen blackouts. This may affect patient monitoring but does not cause injury.
Hamilton Medical recalls C6 ventilators with serial numbers starting 5663-9590 due to loose status indicator board risking water ingress from disinfectants, potentially causing technical faults and unsafe breathing conditions.
Hamilton Medical recalls H900 humidifiers (models 950001, 950004) with software 1.10c due to delayed low water alarm when chamber is empty, risking undetected water absence during medical ventilation.
Hamilton Medical recalls G5 ventilators with software versions 2.60 or older due to potential risk of unassisted breathing. Affected units have serial numbers 16192 and lower.
Hamilton Medical recalls C3 ventilators due to battery gauge potentially showing higher charge than actual. Affected units may need battery replacement to prevent incorrect shutdowns.
Hamilton Medical recalls C2 Ventilators due to battery gauge potentially showing higher charge than actual. This could lead to unexpected shutdowns during critical care. Affected units have serial numbers and were sold in hospitals.
Hamilton Medical recalls C1 ventilators with specific serial numbers due to potential unintended shutdowns. Affected units may shut down unexpectedly with alarms. Contact for remedy details.
Hamilton Medical recalls C3 ventilators with potential for unintended shutdown due to control board issues. Affected units may shut down unexpectedly with alarms. Contact for remedy details.