2012 Ford F-450 recalls (14)
14 NHTSA safety recalls cover the 2012 Ford F-450. Owners have filed 17 complaints with NHTSA about this model year. Every recall repair is free at any Ford dealer.
Is yours affected? Recalls cover ranges of VINs, not every 2012 Ford F-450. Check your F-450 by VIN and confirm open recalls at NHTSA.gov.
Every 2012 Ford F-450 recall
Each campaign as NHTSA published it: what is wrong, what can happen, and the fix. Newest first.
Power Train · NHTSA 15V175000
- Problem
- Ford Motor Company (Ford) is recalling certain model year 2011-2015 Ford F-350, F-450, and F-550 trucks manufactured February 22, 2010, to January 30, 2015, and equipped with ambulance or fire engine preparation packages. The affected vehicles may detect an incorrect Exhaust Gas Temperature Sensor (EGT) fault indicating that the vehicle is too hot, causing the engine management system to shut down the engine and prevent its immediate restart.
- Risk
- Engine shut down and a subsequent cool down period may delay medical treatment or assistance to those needing it, increasing their risk of injury.
- Fix
- Ford will notify owners, and dealers will update the Powertrain Control Module (PCM) software, free of charge. The recall began on April 22, 2015. Owners may contact Ford customer service at 1-866-436-7332. Ford's number for this recall is 15S09.
Equipment · NHTSA 14V327000
- Problem
- Stahl is recalling certain model year 2009-2014 Ford F-350 Super Duty, F-450 Super Duty, and F-550 Super Duty vehicles modified by Stahl and equipped with certain Muncie Power Products PTO Assemblies. In the affected vehicles, oil may leak from the PTO pressure switch onto a thermal blanket covering the exhaust.
- Risk
- The leaking oil may soak into the thermal blanket covering the exhaust, which when combined with heat from exhaust, may result in an increased risk of fire.
- Fix
- Stahl will notify owners, and dealers will install a new pressure switch kit that moves the switch away from the exhaust system, free of charge. Owners may contact Stahl customer service at 1-800-277-8245, or Muncie at 1-800-367-7867.
Equipment · NHTSA 14V496000
- Problem
- Versalift East, LLC (Versalift) is recalling certain Aerial devices manufactured on 2009-2013 Ford, F-350, F-450, and F-550 Super Duty 6.8L gas engine chassis, modified by Versalift and equipped with certain Muncie Power Products FR67 PTO Assemblies. In the affected vehicles, oil may leak from the PTO pressure switch onto a thermal blanket covering the exhaust.
- Risk
- The leaking oil may soak into the thermal blanket covering the exhaust, which when combined with heat from exhaust, may result in an increased risk of fire.
- Fix
- Versalift will notify owners, and dealers will install a new pressure switch kit that moves the switch away from the exhaust system, free of charge. The recall began on September 14, 2014. Owners may contact Versalift customer service at 1-888-866-1400.
Equipment · NHTSA 14V379000
- Problem
- Utility Truck Equipment Company, LLC (Utility Truck) is recalling certain model year 2010-2013 UTLI41A, 2011 UTLN41, and 2012 UTLN46 aerial trucks manufactured December 2010 to September 2013 equipped with certain Muncie Power Products PTO Assemblies installed on 2010-2013 Ford F-350, F-450 and F-550 vehicles. In the affected vehicles, oil may leak from the PTO pressure switch onto a thermal blanket covering the exhaust.
- Risk
- The leaking oil may soak into the thermal blanket covering the exhaust, which when combined with heat from exhaust, may result in an increased risk of fire.
- Fix
- Utility Truck will notify owners, and dealers will install a new pressure switch kit that moves the switch away from the exhaust system, free of charge. The recall began in June 2014. Owners may contact Utility Truck customer service at 1-254-857-8813.
Equipment · NHTSA 14V382000
- Problem
- Somerset Welding & Steel, doing business as J&J Truck equipment (J&J), is recalling certain model year 2009-2013 Ford F-350, F-450, and F-550 Super Duty chassis with 6.8L gasoline engines modified by J&J to be equipped with certain Muncie Power Products PTO Assemblies. In the affected vehicles, oil may leak from the PTO pressure switch onto a thermal blanket covering the exhaust.
- Risk
- The leaking oil may soak into the thermal blanket covering the exhaust, which when combined with heat from exhaust, may result in an increased risk of fire.
- Fix
- Somerset will notify owners, and dealers will install a new pressure switch kit that moves the switch away from the exhaust system, free of charge. The recall began August 2014. Owner's may contact Somerset customer service at 1-800-777-2671.
Equipment · NHTSA 14V507000
- Problem
- Jerr-Dan Corporation (Jerr-Dan) is recalling certain model year 2009-2014 Ford F-350 Super Duty, F-450 Super Duty, and F-550 Superduty chassis modified by Jerr-Dan and equipped with certain Muncie Power Products PTO Assemblies. In the affected vehicles, oil may leak from the PTO pressure switch onto a thermal blanket covering the exhaust.
- Risk
- The leaking oil may soak into the thermal blanket covering the exhaust, which when combined with heat from exhaust, may result in an increased risk of fire.
- Fix
- Jerr-Dan will notify owners, and dealers will install a new pressure switch kit that moves away from the exhaust system, free of charge. The recall began in October 2014. Owners may contact Jerr-Dan customer service at 1-800-926-9666.
Equipment · NHTSA 14V498000
- Problem
- PJ's Truck Bodies & Equipment Co., (PJ's) is recalling certain 2009-2013 Ford F-350, F-450, and F-550 Super Duty chassis modified by PJ's and equipped with certain Muncie Power Products PTO Assemblies. In the affected vehicles, oil may leak from the PTO pressure switch onto a thermal blanket covering the exhaust.
- Risk
- The leaking oil may soak into the thermal blanket covering the exhaust, which when combined with heat from exhaust, may result in an increased risk of fire.
- Fix
- PJ's has notified owners and dealers will install a new pressure switch kit that moves the switch away from the exhaust system, free of charge. The recall began on August 28, 2014. Owners may contact PJ's customer service at 1-866-475-8782.
Equipment · NHTSA 14V494000
- Problem
- Vanair Manufacturing, Inc. (Vanair) is recalling certain model year 2009-2013 Ford F-350, F-450, and F-550 SuperDuty chassis modified by Vanair and equipped with certain Muncie Power Products PTO Assemblies used with model 60-85 UDSM, 125-185 USDM, and Genair 125-185 driven air compressor systems. In the affected vehicles, oil may leak from the PTO pressure switch onto a thermal blanket covering the exhaust.
- Risk
- The leaking oil may soak into the thermal blanket covering the exhaust, which when combined with heat from exhaust, may result in an increased risk of fire.
- Fix
- Vanair will notify owners, and dealers will inspect and install a new pressure switch kit that moves the switch away from the exhaust system, free of charge. The recall began in November 2014. Owners may contact Vanair customer service at 1-800-526-8817.
Equipment · NHTSA 14V360000
- Problem
- Palfleet Truck Equipment Company, LLC (Palfleet) is recalling certain model year 2009-2013 Ford F-350, F-450, and F-550 super duty vehicles modified by Palfleet and equipped with certain Muncie Power Products PTO Assemblies. In the affected vehicles, oil may leak from the PTO pressure switch onto a thermal blanket covering the exhaust.
- Risk
- The leaking oil may soak into the thermal blanket covering the exhaust, which when combined with heat from exhaust, may result in an increased risk of fire.
- Fix
- Palfleet will notify owners, and dealers will install a new pressure switch kit that moves the switch away from the exhaust system, free of charge. The recall began on July 29, 2014. Owners may contact Palfleet customer service at 1- 502-376-2458.
Equipment · NHTSA 14V326000
- Problem
- Manning Equipment Inc. LLC (Manning) is recalling certain model year 2012-2013 Ford F-350 Super Duty, F-450 Super Duty, and F-550 Super Duty vehicles modified by Manning and equipped with certain Muncie Power Products PTO Assemblies. In the affected vehicles, oil may leak from the PTO pressure switch onto a thermal blanket covering the exhaust.
- Risk
- The leaking oil may soak into the thermal blanket covering the exhaust, which when combined with heat from exhaust, may result in an increased risk of fire.
- Fix
- Manning will notify owners, and dealers will install a new pressure switch kit that moves the switch away from the exhaust system, free of charge. This action is the same as the service campaign action. The recall began in July 2014. Owners may contact Manning at 1-800-876-8768.
Equipment · NHTSA 14V328000
- Problem
- Iowa Mold Tooling Co., Inc. will notify owners and dealers to inspect the Muncie PTO pressure switch to determine if it is from the range of defective switches and if required, remove the pressure switch assembly and put a plug in the port where the PTO switch had been installed. This switch was never being utilized. This will be done free of charge. The recall is expected to begin in mid-July 2014. Owners may contact Iowa Mold Tooling Co., Inc. at 1-800-247-5958.
- Risk
- The leaking oil may soak into the thermal blanket covering the exhaust, which when combined with heat from exhaust, may result in an increased risk of fire.
- Fix
- Iowa Mold Tooling Co., Inc. will notify owners, and dealers will install a new pressure switch kit that moves the switch away from the exhaust system, free of charge. The recall began on July 28, 2014. Owners may contact Iowa Mold Tooling Co., Inc. at 1-800-247-5958.
Engine · NHTSA 13V535000
- Problem
- Ford Motor Company (Ford) is recalling certain model year 2011-2012 F-350/450/550 Ambulance Package vehicles manufactured February 22, 2010, through October 19, 2012 and equipped with a 6.7L diesel engine. Due to an exhaust sensor problem, the vehicles may experience loss of power followed by an engine stall.
- Risk
- An unexpected engine stall increases the risk of a crash. Additionally, if this were to occur when the ambulance is transporting a patient, there is an increased risk of injury to the patient.
- Fix
- Ford will notify owners, and dealers will replace the exhaust gas temperature sensor, free of charge. The recall began on November 25, 2013. Owners may contact Ford Motor Company Customer Relationship Center at 1-866-436-7332. Ford's recall campaign number is 13S10.
Engine and Engine Cooling · NHTSA 13V380000
- Problem
- Manning Equipment Inc. LLC (Manning) is recalling certain model year 2012 Ford F-350, F-450 and F-550 gasoline engined dual rear wheel chassis vehicles manufactured October 2011 through June 2012. The tailpipe on the exhaust system does not extend out beyond the edge of the body, allowing heat to build up in rear curbside storage compartment.
- Risk
- Excessive heat build up in rear compartment could result in fire.
- Fix
- Manning Equipment has notified owners, and dealers will install tailpipe extensions free of charge. The recall has already begun. Owners may contact Manning Equipment at 1-502-426-5210.
Power Train · NHTSA 11V582000
- Problem
- FORD IS RECALLING CERTAIN MODEL YEAR 2011 F-150 VEHICLES MANUFACTURED FROM SEPTEMBER 9, 2011, THROUGH SEPTEMBER 22, 2011, AND MODEL YEAR 2012 F-250, F-350, F-450 AND F-550 HEAVY DUTY VEHICLES MANUFACTURED FROM SEPTEMBER 12, 2011, THROUGH SEPTEMBER 22, 2011. THESE VEHICLES FAIL TO COMPLY WITH THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NUMBER 114, THEFT PROTECTION. THE TRANSMISSION CAN BE SHIFTED OUT OF THE PARK POSITION WITHOUT PRESSING THE BRAKE PEDAL DUE TO BRAKE SHIFT INTERLOCK SWITCH PROBLEM.
- Risk
- THIS WILL ALLOW THE OPERATOR TO INADVERTENTLY SHIFT THE VEHICLE INTO GEAR WITHOUT THE BRAKE PEDAL BEING DEPRESSED, INCREASING THE RISK OF A CRASH OR INJURY TO A NEARBY PEDESTRIAN.
- Fix
- FORD WILL NOTIFY OWNERS, AND DEALERS WILL INSPECT THE BRAKE SHIFT INTERLOCK SWITCH FUNCTION AND REPLACE THE SWITCH IF NECESSARY, FREE OF CHARGE. THE SAFETY RECALL BEGAN ON DECEMBER 22, 2011. OWNERS MAY CONTACT THE FORD MOTOR COMPANY CUSTOMER RELATIONSHIP CENTER AT 1-866-436-7332.
2012 Ford F-450 complaints and service bulletins
Owners filed 17 complaints with NHTSA about the 2012 Ford F-450. Ford has issued at least 143 technical service bulletins (repair instructions to dealers) for this model year. Complaints are unverified owner reports; a recall is the manufacturer’s admission of a safety defect.
Most-reported components
Service bulletins by component
- Engine and Engine Cooling (62)
- Power Train (32)
- Electrical System (31)
- Equipment (20)
- Engine (16)
- Fuel System, Diesel (13)
NHTSA defect investigations covering the 2012 Ford F-450
NHTSA’s Office of Defects Investigation lists this model year in one investigation. An investigation is not a recall; it is how NHTSA decides whether one is needed.
- Vehicle Commanded Engine Shutdown
What people reported
Owners have filed 17 complaints with NHTSA about the 2012 Ford F-450. A few in their own words, shortened. Complaints are unverified and are not proof of a defect or of any recall.
“The contact owns a 2012 Ford F-450. The contact stated that while driving at an undisclosed speed, the vehicle unexpectedly stalled. There was no warning light illuminated. The vehicle failed to restart and was towed back to the residence.”
Complaint filed with NHTSA, not verified by the agency · NHTSA complaint 11723101
“THE A/C COMPRESSOR JUST WENT OUT FOR THE SECOND TIME AND FROM WHAT IT LOOKS TO ME IS WHY THE SECOND FAILURE HAS OCCURRED IS BECAUSE THE DEALERSHIP DID NOT REPLACE THE CONDENSER AS WAS REQUIRED AND ALSO PAID FOR BY ME.”
Complaint filed with NHTSA, not verified by the agency · NHTSA complaint 11161082
“KEY IN IGNITION CIRCUIT IS OPEN - ENGINE LIGHT ON ' FIXD INDICATES INSPECTION ISSUE.”
Complaint filed with NHTSA, not verified by the agency · NHTSA complaint 11375953
“AS PER YOUR ODI RESUME #RQ14-005, MY RV BUILT ON 2012 CHASSIS EXPERIENCED EGT SENSOR MALFUNCTION TO NUMBER 13 AND 14. THIS OCCURRED ON I-75 OUTSIDE OF LEXINGTON, KY. I WAS VERY LUCKY TO BE IN THE RIGHT LANE AND JUST BARELY PULLED TO THE SHOULDER BEFORE THE ENGINE SHUTDOWN.”
Complaint filed with NHTSA, not verified by the agency · NHTSA complaint 10682653
“WE HAVE TO REPLACE OUR FUEL TANK BECAUSE THE LINING HAS DELAMINATED. WE HAVE ALREADY HAD TO REPLACE THE ENGINE WHICH MAY HAVE BEEN A RESULT OF THE LINING DETERIORATION.”
Complaint filed with NHTSA, not verified by the agency · NHTSA complaint 11310536
Search the official database: NHTSA. Excerpts are quoted from the public record, shortened at a sentence and with personal details removed.
Check your F-450 by VIN
Not every 2012 Ford F-450 is in every recall. Enter your 17-character VIN to see the recalls on record for your exact vehicle, then confirm which are still open at NHTSA.gov or with any Ford dealer.