2010 Ford F-350 recalls (11)
11 NHTSA safety recalls cover the 2010 Ford F-350. Owners have filed 52 complaints with NHTSA about this model year. Every recall repair is free at any Ford dealer.
Is yours affected? Recalls cover ranges of VINs, not every 2010 Ford F-350. Check your F-350 by VIN and confirm open recalls at NHTSA.gov.
Every 2010 Ford F-350 recall
Each campaign as NHTSA published it: what is wrong, what can happen, and the fix. Newest first.
Steering · NHTSA 20E090000
- Problem
- Icon Vehicle Dynamics, LLC (Icon) is recalling all 05-UP FSD 2.5 Centerline Stabilizer Kits with part number 65050. The kits were sold as an accessory for certain 2005-2021 Ford F-250 4X4 and F-350 4X4 pickup trucks. The foam ring inside the stabilizer "through shaft" may block the piston ports, possibly causing the steering to lock up.
- Risk
- If the steering locks, it can increase the risk of a crash.
- Fix
- Icon will notify owners, and dealers will install a new shock assembly with a revised foam ring and steel support disc, free of charge. The recall began December 21, 2020. Owners may contact Icon customer service at 1-951-689-4266.
Equipment · NHTSA 14V327000
- Problem
- Stahl is recalling certain model year 2009-2014 Ford F-350 Super Duty, F-450 Super Duty, and F-550 Super Duty vehicles modified by Stahl and equipped with certain Muncie Power Products PTO Assemblies. In the affected vehicles, oil may leak from the PTO pressure switch onto a thermal blanket covering the exhaust.
- Risk
- The leaking oil may soak into the thermal blanket covering the exhaust, which when combined with heat from exhaust, may result in an increased risk of fire.
- Fix
- Stahl will notify owners, and dealers will install a new pressure switch kit that moves the switch away from the exhaust system, free of charge. Owners may contact Stahl customer service at 1-800-277-8245, or Muncie at 1-800-367-7867.
Equipment · NHTSA 14V496000
- Problem
- Versalift East, LLC (Versalift) is recalling certain Aerial devices manufactured on 2009-2013 Ford, F-350, F-450, and F-550 Super Duty 6.8L gas engine chassis, modified by Versalift and equipped with certain Muncie Power Products FR67 PTO Assemblies. In the affected vehicles, oil may leak from the PTO pressure switch onto a thermal blanket covering the exhaust.
- Risk
- The leaking oil may soak into the thermal blanket covering the exhaust, which when combined with heat from exhaust, may result in an increased risk of fire.
- Fix
- Versalift will notify owners, and dealers will install a new pressure switch kit that moves the switch away from the exhaust system, free of charge. The recall began on September 14, 2014. Owners may contact Versalift customer service at 1-888-866-1400.
Equipment · NHTSA 14V379000
- Problem
- Utility Truck Equipment Company, LLC (Utility Truck) is recalling certain model year 2010-2013 UTLI41A, 2011 UTLN41, and 2012 UTLN46 aerial trucks manufactured December 2010 to September 2013 equipped with certain Muncie Power Products PTO Assemblies installed on 2010-2013 Ford F-350, F-450 and F-550 vehicles. In the affected vehicles, oil may leak from the PTO pressure switch onto a thermal blanket covering the exhaust.
- Risk
- The leaking oil may soak into the thermal blanket covering the exhaust, which when combined with heat from exhaust, may result in an increased risk of fire.
- Fix
- Utility Truck will notify owners, and dealers will install a new pressure switch kit that moves the switch away from the exhaust system, free of charge. The recall began in June 2014. Owners may contact Utility Truck customer service at 1-254-857-8813.
Equipment · NHTSA 14V382000
- Problem
- Somerset Welding & Steel, doing business as J&J Truck equipment (J&J), is recalling certain model year 2009-2013 Ford F-350, F-450, and F-550 Super Duty chassis with 6.8L gasoline engines modified by J&J to be equipped with certain Muncie Power Products PTO Assemblies. In the affected vehicles, oil may leak from the PTO pressure switch onto a thermal blanket covering the exhaust.
- Risk
- The leaking oil may soak into the thermal blanket covering the exhaust, which when combined with heat from exhaust, may result in an increased risk of fire.
- Fix
- Somerset will notify owners, and dealers will install a new pressure switch kit that moves the switch away from the exhaust system, free of charge. The recall began August 2014. Owner's may contact Somerset customer service at 1-800-777-2671.
Equipment · NHTSA 14V507000
- Problem
- Jerr-Dan Corporation (Jerr-Dan) is recalling certain model year 2009-2014 Ford F-350 Super Duty, F-450 Super Duty, and F-550 Superduty chassis modified by Jerr-Dan and equipped with certain Muncie Power Products PTO Assemblies. In the affected vehicles, oil may leak from the PTO pressure switch onto a thermal blanket covering the exhaust.
- Risk
- The leaking oil may soak into the thermal blanket covering the exhaust, which when combined with heat from exhaust, may result in an increased risk of fire.
- Fix
- Jerr-Dan will notify owners, and dealers will install a new pressure switch kit that moves away from the exhaust system, free of charge. The recall began in October 2014. Owners may contact Jerr-Dan customer service at 1-800-926-9666.
Equipment · NHTSA 14V498000
- Problem
- PJ's Truck Bodies & Equipment Co., (PJ's) is recalling certain 2009-2013 Ford F-350, F-450, and F-550 Super Duty chassis modified by PJ's and equipped with certain Muncie Power Products PTO Assemblies. In the affected vehicles, oil may leak from the PTO pressure switch onto a thermal blanket covering the exhaust.
- Risk
- The leaking oil may soak into the thermal blanket covering the exhaust, which when combined with heat from exhaust, may result in an increased risk of fire.
- Fix
- PJ's has notified owners and dealers will install a new pressure switch kit that moves the switch away from the exhaust system, free of charge. The recall began on August 28, 2014. Owners may contact PJ's customer service at 1-866-475-8782.
Equipment · NHTSA 14V494000
- Problem
- Vanair Manufacturing, Inc. (Vanair) is recalling certain model year 2009-2013 Ford F-350, F-450, and F-550 SuperDuty chassis modified by Vanair and equipped with certain Muncie Power Products PTO Assemblies used with model 60-85 UDSM, 125-185 USDM, and Genair 125-185 driven air compressor systems. In the affected vehicles, oil may leak from the PTO pressure switch onto a thermal blanket covering the exhaust.
- Risk
- The leaking oil may soak into the thermal blanket covering the exhaust, which when combined with heat from exhaust, may result in an increased risk of fire.
- Fix
- Vanair will notify owners, and dealers will inspect and install a new pressure switch kit that moves the switch away from the exhaust system, free of charge. The recall began in November 2014. Owners may contact Vanair customer service at 1-800-526-8817.
Equipment · NHTSA 14V360000
- Problem
- Palfleet Truck Equipment Company, LLC (Palfleet) is recalling certain model year 2009-2013 Ford F-350, F-450, and F-550 super duty vehicles modified by Palfleet and equipped with certain Muncie Power Products PTO Assemblies. In the affected vehicles, oil may leak from the PTO pressure switch onto a thermal blanket covering the exhaust.
- Risk
- The leaking oil may soak into the thermal blanket covering the exhaust, which when combined with heat from exhaust, may result in an increased risk of fire.
- Fix
- Palfleet will notify owners, and dealers will install a new pressure switch kit that moves the switch away from the exhaust system, free of charge. The recall began on July 29, 2014. Owners may contact Palfleet customer service at 1- 502-376-2458.
Equipment · NHTSA 14V328000
- Problem
- Iowa Mold Tooling Co., Inc. will notify owners and dealers to inspect the Muncie PTO pressure switch to determine if it is from the range of defective switches and if required, remove the pressure switch assembly and put a plug in the port where the PTO switch had been installed. This switch was never being utilized. This will be done free of charge. The recall is expected to begin in mid-July 2014. Owners may contact Iowa Mold Tooling Co., Inc. at 1-800-247-5958.
- Risk
- The leaking oil may soak into the thermal blanket covering the exhaust, which when combined with heat from exhaust, may result in an increased risk of fire.
- Fix
- Iowa Mold Tooling Co., Inc. will notify owners, and dealers will install a new pressure switch kit that moves the switch away from the exhaust system, free of charge. The recall began on July 28, 2014. Owners may contact Iowa Mold Tooling Co., Inc. at 1-800-247-5958.
Equipment · NHTSA 14V307000
- Problem
- Tactical Vehicle Outfitters (Tactical) is recalling certain model year 2010-2014 Ford F-350 and F-550 vehicles modified by Tactical and equipped with certain Muncie Power Products PTO Assemblies. In the affected vehicles, oil may leak from the PTO pressure switch onto a thermal blanket covering the exhaust.
- Risk
- The leaking oil may soak into the thermal blanket covering the exhaust, which when combined with heat from exhaust, may result in an increased risk of fire.
- Fix
- Tactical will notify owners, and dealers will install a new PTO pressure switch, free of charge. The recall began on August 1, 2014. Owners may contact Tactical customer service at 1-405-603-6700.
2010 Ford F-350 complaints and service bulletins
Owners filed 52 complaints with NHTSA about the 2010 Ford F-350, reporting 1 crashes, 2 fires, 1 injuries. Ford has issued at least 43 technical service bulletins (repair instructions to dealers) for this model year. Complaints are unverified owner reports; a recall is the manufacturer’s admission of a safety defect.
Most-reported components
Service bulletins by component
- Engine and Engine Cooling (19)
- Power Train (9)
- Equipment (7)
- Electrical System (6)
- Engine (2)
- Equipment Adaptive/Mobility (2)
What people reported
Owners have filed 52 complaints with NHTSA about the 2010 Ford F-350. A few in their own words, shortened. Complaints are unverified and are not proof of a defect or of any recall.
- Injury reported
“TWO TO THREE WEEKS AGO WHILE DRIVING ON THE HIGHWAY IN MY FORD F350 SRW, $WD, CREW CAB TRUCK I WENT OVER A BRIDGE. WENT I CAME OFF THE BRIDGE AND WENT OVER A LITTLE BUMP MY VEHICLE STARTED SHAKING UNCONTROLLABLY. FIRST I WAS YANKED TO THE LEFT AND THEN I WAS ABLE TO STEER IT TO THE RIGHT.”
Complaint filed with NHTSA, not verified by the agency · NHTSA complaint 11348979
- Fire
“THE VEHICLE IS A FLEET VEHICLE. IT WAS GOING WEST ON I70 NEAR THE MAMM CREEK EXIT WHEN THE TRANSFER CASE EXPLODED & STARTED THE OIL THAT WAS IN IT ON FIRE. THE DRIVER PULLED OFF THE ROAD AND USED 2 SMALL FIRE EXTINGUISHERS TO TRY TO PUT IT OUT BUT WASN'T ABLE TO.”
Complaint filed with NHTSA, not verified by the agency · NHTSA complaint 10652020
- Fire
“THE CONTACT OWNS A 2010 FORD F-350 SD. WHILE THE VEHICLE WAS PARKED AND TURNED OFF, THE ENGINE COMPARTMENT CAUGHT FIRE WITHOUT WARNING. THE FIRE DEPARTMENT EXTINGUISHED THE FIRE. A POLICE REPORT WAS FILED AND THERE WERE NO INJURIES. THE VEHICLE WAS TOWED TO THE DEALER, BUT WAS NOT DIAGNOSED.”
Complaint filed with NHTSA, not verified by the agency · NHTSA complaint 10939476
“LOSS OF CONTROL WHEN DRIVING ON BUMPY SECTION OF FREEWAY, DUE TO EXTREME SHAKING OF FRONT END. NO ACCIDENT, BUT HAD TO SLOW DOWN TO LESS THAN 10 MILES AN HOUR BEFORE CURVE TO REGAIN CONTROL.”
Complaint filed with NHTSA, not verified by the agency · NHTSA complaint 10650143
- Crash
“RAILROAD HYRAIL VEHICLE EQUIPPED, AFTER MARKET, WITH HYRAIL WHEEL ASSEMBLIES WHICH ALLOW THE VEHICLE TO OPERATE ON RAILROAD TRACKS. ONCE HYRAIL (FLANGED) WHEELS ARE RETRACTED, THE VEHICLE IS OPERATED OVER THE HIGHWAYS AND PUBLIC ROADS LIKE ANY OTHER VEHICLE.”
Complaint filed with NHTSA, not verified by the agency · NHTSA complaint 10484745
Search the official database: NHTSA. Excerpts are quoted from the public record, shortened at a sentence and with personal details removed.
Check your F-350 by VIN
Not every 2010 Ford F-350 is in every recall. Enter your 17-character VIN to see the recalls on record for your exact vehicle, then confirm which are still open at NHTSA.gov or with any Ford dealer.