Stop using now Medical device recall · FDA · Published May 2, 2018

Ad-Tech Drill Sleeve Guides Recall: Risk of Drill Bit Seizing During Surgery

Ad-Tech Medical recalls drill sleeve guides DSG-6.3-090-2.4N with specific batch numbers due to potential drill bit seizing during skull surgery. Affected units may cause serious injury.

🇺🇸 FDA recall #Z-2539-2018Medical deviceAd-Tech Medical ›
Take action

Contact the company

Recalling firmAd-Tech Medical Instrument Corporation400 W Oakview Pkwy · Oak Creek, WI 53154-7213
✎ GovInfoNow plain-language explainer

Ad-Tech Medical is recalling drill sleeve guides DSG-6.3-090-2.4N that could cause drill bits to seize during skull surgery. This poses a serious risk to patients undergoing neurological procedures. Read more at govinfonow.com/recall/71224-ad-tech-drill-sleeve-guides-recall-risk-of-drill-bit.

Source Summary by GovInfoNow · govinfonow.com/recall/71224-ad-tech-drill-sleeve-guides-recall-risk-of-drill-bit · Updated August 21, 2026 · FDA enforcement record: FDA #Z-2539-2018

Cite this page

“Ad-Tech Drill Sleeve Guides Recall: Risk of Drill Bit Seizing During Surgery.” GovInfoNow, updated August 21, 2026. https://govinfonow.com/recall/71224-ad-tech-drill-sleeve-guides-recall-risk-of-drill-bit. Based on FDA recall #Z-2539-2018 (https://api.fda.gov/device/enforcement.json?search=recall_number:%22Z-2539-2018%22&limit=1).

The FDA announced on May 2, 2018, that Ad-Tech Medical Instrument Corporation is recalling Drill Sleeve Guides DSG-6-3-090-2.4N utilizing raw material RM0677 due to a diameter under tolerance that may cause the drill bit to seize during surgery.

How to tell if you have it

  • Brand: Ad-Tech Medical
  • Product: AD-TECH Medical Instrument Corporation Drill Sleeve Guides DSG-6-3-090-2.4N
  • Catalog Number: DSG-6.3-090-2.4N
  • Raw Material: RM0677
  • Lots: 107104 (710220), 114390 (715001), 111423 (716180), 105176 (613121), 113775 (719190), 115847 (712211), 113776 (719190), 115000 (714201), 114724 (711101), 116389 (712121), 117146 (810110)
  • Vendor: 00-0001062
  • Units Affected: 65

The hazard

The diameter of the drill sleeve guide raw material was found to be under tolerance, potentially resulting in the drill bit seizing in the guide during surgery.

Context

GovInfoNow's records show Ad-Tech Medical Instrument Corporation has 7 other recalls on record since December 20, 2017. Other recent recalls of similar products include Aju Pharm Genesis Dual Thread Screw-In Anchor Recall (December 17, 2025), Surgify Halo 5.4mm Drill Risk (April 30, 2026), and Medline DEXLOCK Achilles Repair Kits (November 11, 2025).

How to tell if you have this one

Check for batch numbers 107104 (710220), 114390 (715001), 111423 (716180), and other listed numbers on the product. These guides are used with Ad-Tech Cranial Drill Bits for skull procedures.

  • Brand
    Ad-Tech Medical
  • Category
    Medical device
Based on the official FDA remedy

What to do — step by step

  1. Stop Using Now

    Immediately stop using the drill sleeve guides if they have the listed batch numbers.

Where it went and when

Where it was distributed

Distributed nationwide and abroad; the notice names 12 states.

Alaska: nationwideAKMaine: nationwideMEVermont: nationwideVTNew Hampshire: named in the noticeNHWashington: nationwideWAIdaho: nationwideIDMontana: nationwideMTNorth Dakota: nationwideNDMinnesota: nationwideMNIllinois: named in the noticeILWisconsin: nationwideWIMichigan: named in the noticeMINew York: named in the noticeNYRhode Island: nationwideRIMassachusetts: nationwideMAOregon: named in the noticeORNevada: nationwideNVWyoming: nationwideWYSouth Dakota: nationwideSDIowa: nationwideIAIndiana: nationwideINOhio: named in the noticeOHPennsylvania: named in the noticePANew Jersey: nationwideNJConnecticut: nationwideCTCalifornia: named in the noticeCAUtah: named in the noticeUTColorado: nationwideCONebraska: nationwideNEMissouri: nationwideMOKentucky: nationwideKYWest Virginia: named in the noticeWVVirginia: nationwideVAMaryland: nationwideMDDelaware: nationwideDEArizona: nationwideAZNew Mexico: nationwideNMKansas: nationwideKSArkansas: nationwideARTennessee: nationwideTNNorth Carolina: nationwideNCSouth Carolina: named in the noticeSCDistrict of Columbia: nationwideDCOklahoma: nationwideOKLouisiana: nationwideLAMississippi: nationwideMSAlabama: nationwideALGeorgia: nationwideGAHawaii: nationwideHITexas: nationwideTXFlorida: named in the noticeFL

FDA distribution: “US Nationwide distribution in the states of CA, FL, IL, MI, NH, NY, OH, OR, PA, SC, UT, WV. Worldwide distribution to Canada, Denmark, Germany, India, Israel, Japan, Russia, South Korea, Taiwan, United Kingdom.” States read from FDA’s own wording; “not listed” means the notice does not name it.

Named in the notice: California, Florida, Illinois, Michigan, New Hampshire, New York, Ohio, Oregon, Pennsylvania, South Carolina, Utah, West Virginia.

Recall timeline

FDA terminated this recall 9 months after the firm started it.

1. Firm started the recall: May 2, 201812. FDA classified it Class II: Jul 25, 201823. Published in FDA’s Enforcement Report: Aug 1, 201834. FDA terminated the recall: Feb 8, 2019420182019
  1. Firm started the recall
  2. FDA classified it Class II
  3. Published in FDA’s Enforcement Report
  4. FDA terminated the recall

Dates from the agency record only; steps without a date are left out.

Similar recalls

Latest medical device recalls

Keep exploring

Where this comes from

The facts (hazard, remedy, dates, manufacturer) are pulled from the official FDA recall record. The plain-language summary and step-by-step checklist are written by GovInfoNow to make the official notice easier to act on — they don’t replace it.

  • Official source: FDA Recall #Z-2539-2018 (May 2, 2018) — FDA publishes no per-recall page; this is the official machine-readable enforcement record. Search FDA recalls for Z-2539-2018 to see it in context.