Skip to content
Use caution Medical device recall · FDA · Published August 6, 2026

IMRIS ORT200 Operating Room Table Recall: Risk of Patient Injury from Mechanical Failure

IMRIS recalls ORT200 operating room tables with potential mechanical failure causing unintended patient movement during procedures. Affected units include specific serial numbers and part numbers. Contact IMRIS for remedy details.

🇺🇸 FDA recall #Z-3033-2026Medical deviceIMRIS ›
✎ GovInfoNow plain-language explainer

IMRIS is recalling certain operating room tables that may fail to lock properly, risking patient injury during surgery. This could happen if the table moves unexpectedly while a patient is being treated. Read more at govinfonow.com/recall/697845-imris-ort200-operating-room-table-recall-risk-of-patient-injury.

Source Summary by GovInfoNow · govinfonow.com/recall/697845-imris-ort200-operating-room-table-recall-risk-of-patient-injury · Updated September 14, 2026 · FDA enforcement record: FDA #Z-3033-2026

Cite this page

“IMRIS ORT200 Operating Room Table Recall: Risk of Patient Injury from Mechanical Failure.” GovInfoNow, updated September 14, 2026. https://govinfonow.com/recall/697845-imris-ort200-operating-room-table-recall-risk-of-patient-injury. Based on FDA recall #Z-3033-2026 (https://api.fda.gov/device/enforcement.json?search=recall_number:%22Z-3033-2026%22&limit=1).

The FDA announced on Aug. 6, 2026, that IMRIS Imaging Inc is recalling ORT200 operating room tables due to a mechanical failure risk in the linear actuator and rotational lock mechanism. The agency issued recall number Z-3033-2026 for the voluntary Class II action affecting six units distributed worldwide.

How to tell if you have it

  • Brand: IMRIS
  • Product: ORT200 operating room table, including the ORT200 Covered Table Assembly, Reconditioned
  • Part Number 113821-600 - Serial Numbers: 10003754, 10006997
  • Part Number 114148-000 - UDI-DI: 00857534006349, Serial Numbers: 10005189, 10005190, 10004463, 10004997

The hazard

The linear actuator and rotational lock mechanism components may experience a mechanical failure that prevents the system from transitioning between locked and unlocked state. This may pose a risk of injury to the patient if unintended rotational movement occurs during a procedure.

Context

GovInfoNow's records show IMRIS Imaging Inc has one other recall on record since Dec. 8, 2025: the HFD100 Head Fixation Device Recall regarding torque screw issues. Other recent recalls of similar products include Philips Azurion 3 M15 System Recall (Jan. 26, 2026), Philips Azurion 7 B20 System Recall (Jan. 26, 2026), and Philips Azurion 5 M12 System Software Recalls (Jan. 26, 2026).

How to tell if you have this one

Check for the ORT200 model with specific serial numbers: 10003754, 10006997 (Part 113821-600) or 10005189, 10005190, 10004463, 10004997 (Part 114148-000).

  • Brand
    IMRIS
  • Category
    Medical device
FDA recall event · 2 products

All 2 products in this recall

FDA lists each product line separately under one recall event. Check your product description, lot or code numbers against each row. Every row shares the hazard and remedy on this page.

  • Classification
    Class II
  • Status
    Ongoing
  • Distribution
    Worldwide distribution - US Nationwide and the countries of Canada, China, Japan, Sweden.
Recall numberProduct, codes & lotsQuantity
Z-3033-2026ORT200, operating room table, including the ORT200 Covered Table Assembly, Reconditioned, Part Number 113821-600 and the ORT200 50/60Hz Covered Table Assy V2 Part Number 114148-000; 113821-600 - Serial Numbers: 10003754, 10006997; 114148-000 - UDI-DI: 00857534006349, Serial Numbers: 10005189, 10005190, 10004463, 100049976 units
Z-3034-2026ORT300, operating room table, ORT300 Modular Table Main Unit Assy Part Numbers 114093-000 and 114093-600; 114093-000 - UDI-DI: 00857534006356, Serial Numbers: 10005695, 10002998, 10002997, 10005456, 10005612, 10004372, 10005613, 10002841, 10011119; 114093-600 - UDI-DI: 00857534006462, Serial Numbers: 10002996, 10004515, 10007411, 1000737613 units
Based on the official FDA remedy

What to do — step by step

  1. Check Table Status

    Verify if your ORT200 table has the specific serial numbers listed in the recall notice.

  2. Contact IMRIS

    Reach out to IMRIS Imaging Inc for guidance on next steps and potential remedies.

Where it went and when

Where it was distributed

Distributed nationwide, and outside the U.S.

Alaska: yesAKMaine: yesMEVermont: yesVTNew Hampshire: yesNHWashington: yesWAIdaho: yesIDMontana: yesMTNorth Dakota: yesNDMinnesota: yesMNIllinois: yesILWisconsin: yesWIMichigan: yesMINew York: yesNYRhode Island: yesRIMassachusetts: yesMAOregon: yesORNevada: yesNVWyoming: yesWYSouth Dakota: yesSDIowa: yesIAIndiana: yesINOhio: yesOHPennsylvania: yesPANew Jersey: yesNJConnecticut: yesCTCalifornia: yesCAUtah: yesUTColorado: yesCONebraska: yesNEMissouri: yesMOKentucky: yesKYWest Virginia: yesWVVirginia: yesVAMaryland: yesMDDelaware: yesDEArizona: yesAZNew Mexico: yesNMKansas: yesKSArkansas: yesARTennessee: yesTNNorth Carolina: yesNCSouth Carolina: yesSCDistrict of Columbia: yesDCOklahoma: yesOKLouisiana: yesLAMississippi: yesMSAlabama: yesALGeorgia: yesGAHawaii: yesHITexas: yesTXFlorida: yesFL

FDA distribution: “Worldwide distribution - US Nationwide and the countries of Canada, China, Japan, Sweden.” States read from FDA’s own wording; “not listed” means the notice does not name it.

Distributed nationwide, and outside the U.S.

Recall timeline

FDA published this recall 27 days after the firm started it.

1. Firm started the recall: Aug 6, 202612. FDA classified it Class II: Aug 26, 202623. Published in FDA’s Enforcement Report: Sep 2, 202634. Added to GovInfoNow: Sep 8, 202642026
  1. Firm started the recall
  2. FDA classified it Class II
  3. Published in FDA’s Enforcement Report
  4. Added to GovInfoNow

Dates from the agency record only; steps without a date are left out.

Similar recalls

Latest medical device recalls

Keep exploring

Where this comes from

The facts (hazard, remedy, dates, manufacturer) are pulled from the official FDA recall record. The plain-language summary and step-by-step checklist are written by GovInfoNow to make the official notice easier to act on — they don’t replace it.

  • Official source: FDA Recall #Z-3033-2026 (August 6, 2026) — FDA publishes no per-recall page; this is the official machine-readable enforcement record. Search FDA recalls for Z-3033-2026 to see it in context.
  • Plain-language summary written by qwen3:4b on September 14, 2026, from the official record above. Not reviewed by a person — if it conflicts with the FDA notice, the notice is correct. Report an error on this page.
  • GovInfoNow is an independent service and is not a government agency. We republish official FDA recall data; we don’t issue, amend or administer recalls.
GovInfoNow is an independent guide. We are not FDA or any government agency. Always confirm details with the official recall.Data: CPSC · FDA · NHTSA · USDA