Skip to content
Use caution Medical device recall · FDA · Published November 1, 2018

LivaNova SORIN Heater-Cooler System 3T Recall: Disinfectant Risk

LivaNova recalls SORIN Heater-Cooler System 3T models with potential disinfectant inefficiency and aerosol emission risks. Affected units may need repair or replacement to ensure patient safety during medical procedures.

🇺🇸 FDA recall #Z-0220-2020Medical deviceLivaNova ›
Take action

Contact the company

Recalling firmLivaNova USA Inc.14401 W 65th Way · Arvada, CO 80004-3503
✎ GovInfoNow plain-language explainer

LivaNova is recalling SORIN Heater-Cooler System 3T medical devices due to a risk that the disinfectant may become ineffective, potentially allowing microorganisms to grow. This could lead to infections during surgeries if the device is not properly maintained. The recall also includes a design upgrade to reduce aerosol emissions. Read more at govinfonow.com/recall/69531-livanova-sorin-heater-cooler-system-3t-recall-disinfectant-risk.

Source Summary by GovInfoNow · govinfonow.com/recall/69531-livanova-sorin-heater-cooler-system-3t-recall-disinfectant-risk · Updated August 20, 2026 · FDA enforcement record: FDA #Z-0220-2020

Cite this page

“LivaNova SORIN Heater-Cooler System 3T Recall: Disinfectant Risk.” GovInfoNow, updated August 20, 2026. https://govinfonow.com/recall/69531-livanova-sorin-heater-cooler-system-3t-recall-disinfectant-risk. Based on FDA recall #Z-0220-2020 (https://api.fda.gov/device/enforcement.json?search=recall_number:%22Z-0220-2020%22&limit=1).

The FDA announced on Nov. 1, 2018, that LivaNova USA Inc. is recalling the SORIN Heater-Cooler System 3T due to a chemical reaction that may render the disinfectant ineffective and a design flaw risking aerosol emissions. The agency classified the recall as Class II.

How to tell if you have it

  • Brand: LivaNova
  • Product: SORIN Heater-Cooler System 3T
  • REF: 16-02-85
  • Voltage: 120V~/60Hz
  • Serial numbers: 16S10958 thru 16S16847

The hazard

The firm stated that a chemical reaction may render the disinfectant/water preservative ineffective. Additionally, the recall addresses a design upgrade to reduce the risk of potential aerosol emissions from the device.

Context

GovInfoNow's records show LivaNova USA, Inc. has 18 other recalls on record since Jan. 24, 2018. Recent LivaNova recalls include a Jan. 3, 2025 notice for the SenTiva DUO VNS Therapy Generator regarding the risk of stopping therapy and a Dec. 12, 2024 notice for the SenTiva VNS Generator concerning stopped seizure control. Other recent recalls of similar products include the Philips Allura Xper FD10F Medical System recall (Dec. 15, 2025) and the Steris AMSCO 7052HP Washer/Disinfector recall (Nov. 19, 2025).

How to tell if you have this one

Check for the model number 3T with voltage specifications listed in the product description. Affected units include specific serial numbers ranging from 16S10027 to 16S16847 for the 120V/60Hz version.

  • Brand
    LivaNova
  • Category
    Medical device
Based on the official FDA remedy

What to do — step by step

  1. Check Device Model

    Identify the model number and voltage specifications on the device label to confirm if it's affected.

  2. Contact Manufacturer

    Reach out to LivaNova for guidance on the next steps if the device is confirmed affected.

Where it went and when

Where it was distributed

Distributed nationwide, and outside the U.S.

Alaska: yesAKMaine: yesMEVermont: yesVTNew Hampshire: yesNHWashington: yesWAIdaho: yesIDMontana: yesMTNorth Dakota: yesNDMinnesota: yesMNIllinois: yesILWisconsin: yesWIMichigan: yesMINew York: yesNYRhode Island: yesRIMassachusetts: yesMAOregon: yesORNevada: yesNVWyoming: yesWYSouth Dakota: yesSDIowa: yesIAIndiana: yesINOhio: yesOHPennsylvania: yesPANew Jersey: yesNJConnecticut: yesCTCalifornia: yesCAUtah: yesUTColorado: yesCONebraska: yesNEMissouri: yesMOKentucky: yesKYWest Virginia: yesWVVirginia: yesVAMaryland: yesMDDelaware: yesDEArizona: yesAZNew Mexico: yesNMKansas: yesKSArkansas: yesARTennessee: yesTNNorth Carolina: yesNCSouth Carolina: yesSCDistrict of Columbia: yesDCOklahoma: yesOKLouisiana: yesLAMississippi: yesMSAlabama: yesALGeorgia: yesGAHawaii: yesHITexas: yesTXFlorida: yesFLPuerto Rico: yesPR

FDA distribution: “Worldwide distribution - US Nationwide distribution including sate of PR and countries of Albania, Algeria, Argentina, Armenia, Australia, Austria, Azerbaijan, Bahrain, Bangladesh, Belarus, Belgium, Brazil, Bulgaria, Canada, Chile, China,…” States read from FDA’s own wording; “not listed” means the notice does not name it.

Distributed nationwide, and outside the U.S.

Recall timeline

FDA terminated this recall 3.8 years after the firm started it.

1. Firm started the recall: Nov 1, 201812. FDA classified it Class II: Oct 25, 201923. Published in FDA’s Enforcement Report: Nov 6, 201934. FDA terminated the recall: Aug 4, 2022420182022
  1. Firm started the recall
  2. FDA classified it Class II
  3. Published in FDA’s Enforcement Report
  4. FDA terminated the recall

Dates from the agency record only; steps without a date are left out.

Similar recalls

Latest medical device recalls

Keep exploring

Where this comes from

The facts (hazard, remedy, dates, manufacturer) are pulled from the official FDA recall record. The plain-language summary and step-by-step checklist are written by GovInfoNow to make the official notice easier to act on — they don’t replace it.

  • Official source: FDA Recall #Z-0220-2020 (November 1, 2018) — FDA publishes no per-recall page; this is the official machine-readable enforcement record. Search FDA recalls for Z-0220-2020 to see it in context.
  • Plain-language summary written by qwen3:4b on August 20, 2026, from the official record above. Not reviewed by a person — if it conflicts with the FDA notice, the notice is correct. Report an error on this page.
  • GovInfoNow is an independent service and is not a government agency. We republish official FDA recall data; we don’t issue, amend or administer recalls.
GovInfoNow is an independent guide. We are not FDA or any government agency. Always confirm details with the official recall.Data: CPSC · FDA · NHTSA · USDA