Skip to content
Use caution Medical device recall · FDA · Published January 7, 2019

Smith & Nephew SL PLUS MIA Adapter Recall: Pin Could Disassemble

Smith & Nephew recalls SL PLUS MIA DOUBLE OFFSET ADAPTER RIGHT 60/25MM (S&N 75004613) due to pin disassembly risk. Affected units have specific lot numbers.

🇺🇸 FDA recall #Z-0730-2019Medical deviceSmith & Nephew ›
Take action

Contact the company

Recalling firmSmith & Nephew, Inc.1450 E Brooks Rd · Memphis, TN 38116-1804
✎ GovInfoNow plain-language explainer

What happened, in plain English

Smith & Nephew is recalling a specific surgical adapter because a pin might disassemble, potentially causing injury during use. Owners should check their lot numbers to see if they're affected. Read more at govinfonow.com/recall/69163-smith-nephew-sl-plus-mia-adapter-recall-pin-could-disassemble.

Source Summary by GovInfoNow · govinfonow.com/recall/69163-smith-nephew-sl-plus-mia-adapter-recall-pin-could-disassemble · Updated August 20, 2026 · FDA enforcement record: FDA #Z-0730-2019

Cite this page

“Smith & Nephew SL PLUS MIA Adapter Recall: Pin Could Disassemble.” GovInfoNow, updated August 20, 2026. https://govinfonow.com/recall/69163-smith-nephew-sl-plus-mia-adapter-recall-pin-could-disassemble. Based on FDA recall #Z-0730-2019 (https://api.fda.gov/device/enforcement.json?search=recall_number:%22Z-0730-2019%22&limit=1).

Why it’s dangerous

The pin holding the spring mechanism isn't properly mounted. If it disassembles, it could cause injury during surgical procedures or equipment handling.

Who’s affected

Surgical professionals and medical facilities using the SL PLUS MIA DOUBLE OFFSET ADAPTER RIGHT 60/25MM. Those with lot numbers C63165, C63306, or C63495 are most at risk.

How to tell if you have this one

Check the product label for the lot numbers: C63165, C63306, or C63495. The product is the SL PLUS MIA DOUBLE OFFSET ADAPTER RIGHT 60/25MM with S&N 75004613.

  • Brand
    Smith & Nephew
  • Category
    Medical device
Based on the official FDA remedy

What to do — step by step

  1. Check Product Lot Number

    Look for lot numbers C63165, C63306, or C63495 on the adapter's label.

Where it went and when

Where it was distributed

Distributed in New York and Tennessee, and outside the U.S.

Alaska: not listedAKMaine: not listedMEVermont: not listedVTNew Hampshire: not listedNHWashington: not listedWAIdaho: not listedIDMontana: not listedMTNorth Dakota: not listedNDMinnesota: not listedMNIllinois: not listedILWisconsin: not listedWIMichigan: not listedMINew York: yesNYRhode Island: not listedRIMassachusetts: not listedMAOregon: not listedORNevada: not listedNVWyoming: not listedWYSouth Dakota: not listedSDIowa: not listedIAIndiana: not listedINOhio: not listedOHPennsylvania: not listedPANew Jersey: not listedNJConnecticut: not listedCTCalifornia: not listedCAUtah: not listedUTColorado: not listedCONebraska: not listedNEMissouri: not listedMOKentucky: not listedKYWest Virginia: not listedWVVirginia: not listedVAMaryland: not listedMDDelaware: not listedDEArizona: not listedAZNew Mexico: not listedNMKansas: not listedKSArkansas: not listedARTennessee: yesTNNorth Carolina: not listedNCSouth Carolina: not listedSCDistrict of Columbia: not listedDCOklahoma: not listedOKLouisiana: not listedLAMississippi: not listedMSAlabama: not listedALGeorgia: not listedGAHawaii: not listedHITexas: not listedTXFlorida: not listedFL

FDA distribution: “NY, TN, Germany, Italy, Great Britain, Singapore” States read from FDA’s own wording; “not listed” means the notice does not name it.

States: New York, Tennessee.

Recall timeline

FDA terminated this recall 20 months after the firm started it.

1. Firm started the recall: Jan 7, 201912. FDA classified it Class II: Jan 11, 201923. Published in FDA’s Enforcement Report: Jan 23, 201934. FDA terminated the recall: Sep 17, 2020420192020
  1. Firm started the recall
  2. FDA classified it Class II
  3. Published in FDA’s Enforcement Report
  4. FDA terminated the recall

Dates from the agency record only; steps without a date are left out.

Similar recalls

Latest medical device recalls

Keep exploring

Where this comes from

The facts (hazard, remedy, dates, manufacturer) are pulled from the official FDA recall record. The plain-language summary and step-by-step checklist are written by GovInfoNow to make the official notice easier to act on — they don’t replace it.

  • Official source: FDA Recall #Z-0730-2019 (January 7, 2019) — FDA publishes no per-recall page; this is the official machine-readable enforcement record. Search FDA recalls for Z-0730-2019 to see it in context.
  • Plain-language summary written by qwen3:4b on August 20, 2026, from the official record above. Not reviewed by a person — if it conflicts with the FDA notice, the notice is correct. Report an error on this page.
  • GovInfoNow is an independent service and is not a government agency. We republish official FDA recall data; we don’t issue, amend or administer recalls.
GovInfoNow is an independent guide. We are not FDA or any government agency. Always confirm details with the official recall.Data: CPSC · FDA · NHTSA · USDA