Skip to content
Lower risk Medical device recall · FDA · Published April 21, 2020

Proteus 235 Proton Therapy System: Signature Length Issue Prevents Treatment Resumption

Ion Beam Applications recalls Proteus 235 proton therapy systems where user signatures longer than 10 characters prevent resuming aborted treatments. This medical device affects specific models manufactured between May and November 2019.

🇺🇸 FDA recall #Z-2773-2020Medical deviceIon Beam Applications ›
Take action

Contact the company

Recalling firmIon Beam Applications S.A.Chemin Du Cyclotron 3 · Louvain-la-neuve, Belgium
✎ GovInfoNow plain-language explainer

Ion Beam Applications is recalling Proteus 235 proton therapy systems because user signatures longer than 10 characters can prevent doctors from resuming interrupted treatments. This issue affects medical devices used for cancer treatment that were manufactured between May and November 2019. Read more at govinfonow.com/recall/65347-proteus-235-proton-therapy-system-signature-length-issue-prevents-treatment.

Source Summary by GovInfoNow · govinfonow.com/recall/65347-proteus-235-proton-therapy-system-signature-length-issue-prevents-treatment · Updated August 19, 2026 · FDA enforcement record: FDA #Z-2773-2020

Cite this page

“Proteus 235 Proton Therapy System: Signature Length Issue Prevents Treatment Resumption.” GovInfoNow, updated August 19, 2026. https://govinfonow.com/recall/65347-proteus-235-proton-therapy-system-signature-length-issue-prevents-treatment. Based on FDA recall #Z-2773-2020 (https://api.fda.gov/device/enforcement.json?search=recall_number:%22Z-2773-2020%22&limit=1).

The FDA announced on April 21, 2020, that Ion Beam Applications S.A. is recalling Proteus 235 proton therapy systems due to software issues preventing users from completing aborted treatments. The agency issued recall number Z-2773-2020 for the medical devices.

How to tell if you have it

  • Proteus 235 (brand names: Proteus Plus and Proteus ONE)
  • Serial Number: SAT.140 (US): manufactured May 2019
  • Serial Number: SBF.112 (EU): manufactured October 2019
  • Serial Number: SBF.113 (US): manufactured June 2019
  • Serial Number: SBF.117 (EU): manufactured November 2019

The hazard

The system does not accept user names with more than ten characters, which prevents users from resuming aborted treatment fields based on the Dose Counter Electronic Unit. Additionally, the system rejects local partial archives if the Patient Positioning System position has changed between sessions.

Context

GovInfoNow's records show Ion Beam Applications S.A. has 21 other recalls on record since October 17, 2017. Other recent recalls of similar products include IBA Proton Therapy System PROTEUS 235 Recall: Risk of Mistreatment Without Safety Check (February 3, 2026), Ion Beam Applications PROTEUS 235 Proton Therapy System Recall: Collision Detection Issues (July 10, 2024), and Ion Beam Applications Recalls Proton Therapy Systems Due to Safety Mechanism Deactivation (July 8, 2024). Other recent recalls of similar products include Hitachi Proton Beam Therapy System Recall: Positioning Software Anomaly Risk (February 6, 2026), Hitachi Proton Beam Therapy Systems: Positioning Software Anomaly Risk (February 6, 2026), and Elekta MOSAIQ Oncology System Recall: Risk of Overtreatment in Particle Therapy (December 10, 2025).

How to tell if you have this one

Check for the Proteus 235 system with brand names Proteus Plus or Proteus ONE. These devices were manufactured between May 2019 (US) and November 2019 (EU) with serial numbers starting with SAT.140 or SBF.112 through SBF.117.

  • Brand
    Ion Beam Applications
  • Category
    Medical device
Based on the official FDA remedy

What to do — step by step

  1. Check Signature Length

    Verify if your user signature exceeds 10 characters, which may prevent resuming interrupted treatments.

Where it went and when

Where it was distributed

Distributed nationwide and abroad; the notice names 2 states.

Alaska: nationwideAKMaine: nationwideMEVermont: nationwideVTNew Hampshire: nationwideNHWashington: nationwideWAIdaho: nationwideIDMontana: nationwideMTNorth Dakota: nationwideNDMinnesota: nationwideMNIllinois: nationwideILWisconsin: nationwideWIMichigan: nationwideMINew York: nationwideNYRhode Island: nationwideRIMassachusetts: nationwideMAOregon: nationwideORNevada: nationwideNVWyoming: nationwideWYSouth Dakota: nationwideSDIowa: nationwideIAIndiana: nationwideINOhio: nationwideOHPennsylvania: nationwidePANew Jersey: nationwideNJConnecticut: nationwideCTCalifornia: nationwideCAUtah: nationwideUTColorado: nationwideCONebraska: nationwideNEMissouri: nationwideMOKentucky: nationwideKYWest Virginia: nationwideWVVirginia: named in the noticeVAMaryland: nationwideMDDelaware: nationwideDEArizona: nationwideAZNew Mexico: nationwideNMKansas: nationwideKSArkansas: nationwideARTennessee: nationwideTNNorth Carolina: nationwideNCSouth Carolina: nationwideSCDistrict of Columbia: nationwideDCOklahoma: nationwideOKLouisiana: nationwideLAMississippi: nationwideMSAlabama: nationwideALGeorgia: nationwideGAHawaii: nationwideHITexas: nationwideTXFlorida: named in the noticeFL

FDA distribution: “Worldwide distribution - US Nationwide distribution including in the states of FL, VA and the countries of Belgium, Spain.” States read from FDA’s own wording; “not listed” means the notice does not name it.

Named in the notice: Florida, Virginia.

Recall timeline

FDA terminated this recall 16 months after the firm started it.

1. Firm started the recall: Apr 21, 202012. FDA classified it Class II: Aug 7, 202023. Published in FDA’s Enforcement Report: Aug 19, 202034. FDA terminated the recall: Sep 1, 2021420202021
  1. Firm started the recall
  2. FDA classified it Class II
  3. Published in FDA’s Enforcement Report
  4. FDA terminated the recall

Dates from the agency record only; steps without a date are left out.

Similar recalls

Latest medical device recalls

Keep exploring

Where this comes from

The facts (hazard, remedy, dates, manufacturer) are pulled from the official FDA recall record. The plain-language summary and step-by-step checklist are written by GovInfoNow to make the official notice easier to act on — they don’t replace it.

  • Official source: FDA Recall #Z-2773-2020 (April 21, 2020) — FDA publishes no per-recall page; this is the official machine-readable enforcement record. Search FDA recalls for Z-2773-2020 to see it in context.
  • Plain-language summary written by qwen3:4b on August 19, 2026, from the official record above. Not reviewed by a person — if it conflicts with the FDA notice, the notice is correct. Report an error on this page.
  • GovInfoNow is an independent service and is not a government agency. We republish official FDA recall data; we don’t issue, amend or administer recalls.
GovInfoNow is an independent guide. We are not FDA or any government agency. Always confirm details with the official recall.Data: CPSC · FDA · NHTSA · USDA