Lower risk Medical device recall · FDA · Published September 6, 2023

Randox RX Modena-IVD Clinical Chemistry Analyser Recall: Incorrect Re-run Settings Risk

Randox recalls RX9000 clinical chemistry analyser due to potential incorrect re-run settings causing inaccurate test results. Affected units may need correction to prevent errors in lab testing.

🇺🇸 FDA recall #Z-0201-2024Medical deviceRandox ›
Take action

Contact the company

Recalling firmRandox Laboratories Ltd.55 Diamond Road · Crumlin (North), Ireland
✎ GovInfoNow plain-language explainer

Randox is recalling its RX9000 clinical chemistry analyser because incorrect re-run settings might cause inaccurate test results. This could lead to wrong lab reports if the device is used without proper adjustments. Read more at govinfonow.com/recall/57365-randox-rx-modena-ivd-clinical-chemistry-analyser-recall-incorrect-re.

Source Summary by GovInfoNow · govinfonow.com/recall/57365-randox-rx-modena-ivd-clinical-chemistry-analyser-recall-incorrect-re · Updated August 17, 2026 · FDA enforcement record: FDA #Z-0201-2024

Cite this page

“Randox RX Modena-IVD Clinical Chemistry Analyser Recall: Incorrect Re-run Settings Risk.” GovInfoNow, updated August 17, 2026. https://govinfonow.com/recall/57365-randox-rx-modena-ivd-clinical-chemistry-analyser-recall-incorrect-re. Based on FDA recall #Z-0201-2024 (https://api.fda.gov/device/enforcement.json?search=recall_number:%22Z-0201-2024%22&limit=1).

The FDA announced on Sept. 6, 2023, that Randox Laboratories Ltd. is recalling RX Modena-IVD Clinical Chemistry Analyzers with catalog number RX9000. The hazard involves incorrect sample re-run conditions that may result in reported issues.

How to tell if you have it

  • Brand: Randox
  • Product: RX Modena-IVD Clinical Chemistry Analyser
  • Catalog Number: RX9000
  • UPC: 05055273214963

The hazard

The RX Parameter rerun settings and dilutions used for auto reruns may not meet sample re-run conditions when samples are above or below the assay range. This potential issue may result in incorrectly reported results.

Context

GovInfoNow's records show Randox Laboratories Ltd. has 49 other recalls on record since June 7, 2017. Recent brand recalls include a Cystatin C Reagent recall on June 7, 2024, for missing FDA 510(k) clearance and an Evidence MultiSTAT Software v3.7 recall on April 5, 2024, due to light leak risks. Other recent recalls of similar products include a Siemens Healthcare Syva EMIT 2000 Quinidine Assay recall on July 13, 2026, for inaccurate test results and a Roche cobas pro integrated solutions recall on Jan. 20, 2026, due to software defects causing incorrect lab results.

How to tell if you have this one

Check for the RX9000 model with catalog number RX9000. The recall covers units sold with GTIN: 05055273214963. Lot/batch numbers are not specified in the recall notice.

  • Brand
    Randox
  • Product
    RX Modena-IVD Clinical Chemistry Analyser Catalog Number: RX9000
  • Category
    Medical device
FDA recall event · 5 products

All 5 products in this recall

FDA lists each product line separately under one recall event. Check your product description, lot or code numbers against each row. Every row shares the hazard and remedy on this page.

  • Classification
    Class II
  • Status
    Ongoing
  • Distribution
    US Nationwide distribution including Puerto Rico
Recall numberProduct, codes & lotsQuantity
Z-0198-2024RX Daytona Plus (with ISE)-IVD Clinical Chemistry Analyser Catalog Number: RX4040; GTIN: 05055273207774 Lot/ Batch Number (1) Lot/ Batch Number 7241-0551 7241-0545 7241-0531 7241-0317 7241-02195 units
Z-0199-2024RX Daytona Plus (without ISE)- IVD Clinical Chemistry Analyser (1) RX4041, (2) RX4041R (refurbished); GTIN: 05055273207781 Lot/Batch: (1) 7241-0616 7241-0582 7241-0441 7241-0425 7241-0384 RX4041R: Lot Number: (2) 7241-01496 units
Z-0200-2024RX Imola-IVD Clinical Chemistry Analyzer Catalog Number: RX4900. RX4900R (refurbished); GTIN: 05055273206104 Lot/Batch Number: (1) 7201-0747 7201-0423 7201-0417 7201-0353 7255-0198 7255-0172 7255-0171 7255-0129 7201-1085 7201-1086 7201-1079 7201-1080 7201-0982 7201-0977 7201-0970 7201-0950 7201-0924 7201-0919 7201-0901 7201-0849 7201-0827 7201-0801 7201-0768 7201-0606 7201-0562 7201-0535 7201-0531 7201-0482 (2)¿¿¿¿¿¿¿¿¿¿¿¿¿ 7201-0776 7201-0367 7201-0343¿¿¿¿¿¿¿¿¿¿¿¿¿ ¿¿¿¿ 7201-0348 ¿¿¿¿¿¿¿¿¿¿¿¿¿¿¿¿¿¿¿35 units
Z-0201-2024RX Modena-IVD Clinical Chemistry Analyser Catalog Number: RX9000; GTIN: 05055273214963 Lot/Batch Number:O units
Z-0202-2024RX Monaco-IVD Clinical Chemistry Analyser Catalog Number: RX5000; GTIN: 05055273207750 Lot/ Batch Number 230T240CS0126S 210T240CS0258S S180T240CS0486MA S180T240CS0487MA S180T240CS0483MA S180T240CS0218MA S170T240CS0665MA S160T240CS0111MA S160T240CS0110MA S150T240CS0005MA S140T240CS0185MA S140T240CS0017MA S140T240CS0015MA13 units
Based on the official FDA remedy

What to do — step by step

  1. Check Device Settings

    Verify that re-run settings for sample volume and dilutions are correctly configured to avoid inaccurate test results.

Where it went and when

Where it was distributed

Distributed nationwide.

Alaska: yesAKMaine: yesMEVermont: yesVTNew Hampshire: yesNHWashington: yesWAIdaho: yesIDMontana: yesMTNorth Dakota: yesNDMinnesota: yesMNIllinois: yesILWisconsin: yesWIMichigan: yesMINew York: yesNYRhode Island: yesRIMassachusetts: yesMAOregon: yesORNevada: yesNVWyoming: yesWYSouth Dakota: yesSDIowa: yesIAIndiana: yesINOhio: yesOHPennsylvania: yesPANew Jersey: yesNJConnecticut: yesCTCalifornia: yesCAUtah: yesUTColorado: yesCONebraska: yesNEMissouri: yesMOKentucky: yesKYWest Virginia: yesWVVirginia: yesVAMaryland: yesMDDelaware: yesDEArizona: yesAZNew Mexico: yesNMKansas: yesKSArkansas: yesARTennessee: yesTNNorth Carolina: yesNCSouth Carolina: yesSCDistrict of Columbia: yesDCOklahoma: yesOKLouisiana: yesLAMississippi: yesMSAlabama: yesALGeorgia: yesGAHawaii: yesHITexas: yesTXFlorida: yesFLPuerto Rico: yesPR

FDA distribution: “US Nationwide distribution including Puerto Rico” States read from FDA’s own wording; “not listed” means the notice does not name it.

Distributed nationwide.

Recall timeline

FDA published this recall 2 months after the firm started it.

1. Firm started the recall: Sep 6, 202312. FDA classified it Class II: Oct 31, 202323. Published in FDA’s Enforcement Report: Nov 8, 202332023
  1. Firm started the recall
  2. FDA classified it Class II
  3. Published in FDA’s Enforcement Report

Dates from the agency record only; steps without a date are left out.

✎ GovInfoNow

Questions people ask

Is this recall dangerous?

The recall addresses potential inaccurate test results, not immediate safety risks. The hazard level is low risk.

Similar recalls

Latest medical device recalls

Keep exploring

Where this comes from

The facts (hazard, remedy, dates, manufacturer) are pulled from the official FDA recall record. The plain-language summary and step-by-step checklist are written by GovInfoNow to make the official notice easier to act on — they don’t replace it.

  • Official source: FDA Recall #Z-0201-2024 (September 6, 2023) — FDA publishes no per-recall page; this is the official machine-readable enforcement record. Search FDA recalls for Z-0201-2024 to see it in context.
  • Plain-language summary written by qwen3:4b on August 17, 2026, from the official record above. Not reviewed by a person — if it conflicts with the FDA notice, the notice is correct. Report an error on this page.
  • GovInfoNow is an independent service and is not a government agency. We republish official FDA recall data; we don’t issue, amend or administer recalls.
GovInfoNow is an independent guide. We are not FDA or any government agency. Always confirm details with the official recall.Data: CPSC · FDA · NHTSA · USDA