Lower risk Medical device recall · FDA · Published March 19, 2026

B Braun Hemodialysis Bloodlines Recall: Air Bubbles Risk in Arterial Lines

B Braun recalls specific hemodialysis bloodlines due to potential air bubble accumulation in arterial lines under negative pressure. Affected models include StreamLine Bloodline Long Version (SL-2000M2095L) from June 2025 onward.

🇺🇸 FDA recall #Z-1801-2026Medical deviceB Braun ›
Take action

Contact the company

Recalling firmB Braun Medical Inc824 12th Ave · Bethlehem, PA 18018-3524
✎ GovInfoNow plain-language explainer

What happened, in plain English

B Braun is recalling certain hemodialysis bloodlines that may accumulate small air bubbles in the arterial line during use. This could lead to complications during dialysis treatments if not addressed. Read more at govinfonow.com/recall/49674-b-braun-hemodialysis-bloodlines-recall-air-bubbles-risk-in-arterial.

Source Summary by GovInfoNow · govinfonow.com/recall/49674-b-braun-hemodialysis-bloodlines-recall-air-bubbles-risk-in-arterial · Updated August 18, 2026 · FDA enforcement record: FDA #Z-1801-2026

Cite this page

“B Braun Hemodialysis Bloodlines Recall: Air Bubbles Risk in Arterial Lines.” GovInfoNow, updated August 18, 2026. https://govinfonow.com/recall/49674-b-braun-hemodialysis-bloodlines-recall-air-bubbles-risk-in-arterial. Based on FDA recall #Z-1801-2026 (https://api.fda.gov/device/enforcement.json?search=recall_number:%22Z-1801-2026%22&limit=1).

Why it’s dangerous

The tubing can trap small air bubbles when blood gases adhere to it under negative pressure during dialysis. This may cause air to enter the bloodstream, potentially leading to complications.

Who’s affected

Patients undergoing hemodialysis who use the recalled bloodlines are affected. Healthcare providers using these specific models for dialysis treatments are most at risk.

How to tell if you have this one

Check for the model number SL-2000M2095L on the bloodline. The product was manufactured starting June 29, 2025, and is used in hemodialysis treatments.

  • Brand
    B Braun
  • Category
    Medical device
FDA recall event · 6 products

All 6 products in this recall

FDA lists each product line separately under one recall event. Check your product description, lot or code numbers against each row. Every row shares the hazard and remedy on this page.

  • Classification
    Class I
  • Status
    Ongoing
  • Distribution
    Worldwide distribution - US Nationwide and the country of Canada.
Recall numberProduct, codes & lotsQuantity
Z-1798-2026B. Braun Hemodialysis Bloodlines, STREAMLINE BLOODLINE SET FOR DIALOG DR. Model Number: SL-2010M2096A.; Model Number SL-2010M2096A; UDI-DI Primary: 04046955674992; UDI-DI Unit: 04046955735280; All lots manufactured since 09JUN20253,158,104 units
Z-1799-2026B. Braun Hemodialysis Bloodlines, STREAMLINE BLOODLINE SET FOR DIALOG. Model Number: SL-2010M2096; Model Number: SL-2010M2096; UDI-DI Primary: 04046964367786; UDI-DI Unit: 04046964367779; All lots manufactured since 25MAY2025.2,653,711 units
Z-1800-2026B. Braun Hemodialysis Bloodlines, STREAMLINE FRESENIUS FOR DAVITA. Model Number: SL-2000M2095DA.; Model Number: SL-2000M2095DA; UDI-DI Primary: 04046955776023; UDI-DI Unit: 04046955776016; All lots manufactured since 09JUN2025.1,174,271 units
Z-1801-2026B. Barun Hemodialysis Bloodlines, StreamLine Bloodline Long Version, FMC. Model Number: SL-2000M2095L.; Model Number: SL-2000M2095L; UDI-DI Primary: 04046955348909; UDI-DI Unit: 04046955348893; All lots manufactured since 29JUN2025.328,640 units
Z-1802-2026B. Braun Hemodialysis Bloodlines, LOW VOL, NO CHAMBER 2.6MM PUMP SEGMENT. Model Number: B3-3632M3705.; Model Number: B3-3632M3705; UDI-DI Primary: 04046955348824; UDI-DI Unit: 04046955348817; All lots manufactured since 01AUG2025.4,848 units
Z-1803-2026B Braun Hemodialysis Bloodlines, LOW VOL, NO CHAMBER 4.8MM PUMP SEGMENT. Model Number: B3-4630M4705.; Model Number: B3-4630M4705; UDI-DI Primary: 04046955348848; UDI-DI Unit: 04046955348831; All lots manufactured since 05AUG2025.4,884 units
Based on the official FDA remedy

What to do — step by step

  1. Check Model Number

    Look for the model number SL-2000M2095L on the bloodline packaging or label.

Where it went and when

Where it was distributed

Distributed nationwide, and outside the U.S.

Alaska: yesAKMaine: yesMEVermont: yesVTNew Hampshire: yesNHWashington: yesWAIdaho: yesIDMontana: yesMTNorth Dakota: yesNDMinnesota: yesMNIllinois: yesILWisconsin: yesWIMichigan: yesMINew York: yesNYRhode Island: yesRIMassachusetts: yesMAOregon: yesORNevada: yesNVWyoming: yesWYSouth Dakota: yesSDIowa: yesIAIndiana: yesINOhio: yesOHPennsylvania: yesPANew Jersey: yesNJConnecticut: yesCTCalifornia: yesCAUtah: yesUTColorado: yesCONebraska: yesNEMissouri: yesMOKentucky: yesKYWest Virginia: yesWVVirginia: yesVAMaryland: yesMDDelaware: yesDEArizona: yesAZNew Mexico: yesNMKansas: yesKSArkansas: yesARTennessee: yesTNNorth Carolina: yesNCSouth Carolina: yesSCDistrict of Columbia: yesDCOklahoma: yesOKLouisiana: yesLAMississippi: yesMSAlabama: yesALGeorgia: yesGAHawaii: yesHITexas: yesTXFlorida: yesFL

FDA distribution: “Worldwide distribution - US Nationwide and the country of Canada.” States read from FDA’s own wording; “not listed” means the notice does not name it.

Distributed nationwide, and outside the U.S.

Recall timeline

FDA published this recall 34 days after the firm started it.

1. Firm started the recall: Mar 19, 202612. FDA classified it Class I: Apr 15, 202623. Published in FDA’s Enforcement Report: Apr 22, 202632026
  1. Firm started the recall
  2. FDA classified it Class I
  3. Published in FDA’s Enforcement Report

Dates from the agency record only; steps without a date are left out.

Similar recalls

Latest medical device recalls

Keep exploring

Where this comes from

The facts (hazard, remedy, dates, manufacturer) are pulled from the official FDA recall record. The plain-language summary and step-by-step checklist are written by GovInfoNow to make the official notice easier to act on — they don’t replace it.

  • Official source: FDA Recall #Z-1801-2026 (March 19, 2026) — FDA publishes no per-recall page; this is the official machine-readable enforcement record. Search FDA recalls for Z-1801-2026 to see it in context.
  • Plain-language summary written by qwen3:4b on August 18, 2026, from the official record above. Not reviewed by a person — if it conflicts with the FDA notice, the notice is correct. Report an error on this page.
  • GovInfoNow is an independent service and is not a government agency. We republish official FDA recall data; we don’t issue, amend or administer recalls.
GovInfoNow is an independent guide. We are not FDA or any government agency. Always confirm details with the official recall.Data: CPSC · FDA · NHTSA · USDA