Skip to content
Lower risk Medical device recall · FDA · Published May 13, 2026

HeartMate 3 System Controller Recall: Backup Battery Failures Risk

Thoratec recalls HeartMate 3 System Controller (model 106531US) due to potential 11-volt backup battery failures. Affected users should contact for remedy.

🇺🇸 FDA recall #Z-2519-2026Medical deviceHeartMate ›
Take action

Contact the company

Recalling firmThoratec LLC6035 Stoneridge Dr · Pleasanton, CA 94588-3270
✎ GovInfoNow plain-language explainer

Thoratec is recalling HeartMate 3 System Controllers with model number 106531US because their backup batteries may fail. This could lead to system shutdowns or other issues if the device loses power unexpectedly. Read more at govinfonow.com/recall/49174-heartmate-3-system-controller-recall-backup-battery-failures-risk.

Source Summary by GovInfoNow · govinfonow.com/recall/49174-heartmate-3-system-controller-recall-backup-battery-failures-risk · Updated August 10, 2026 · FDA enforcement record: FDA #Z-2519-2026

Cite this page

“HeartMate 3 System Controller Recall: Backup Battery Failures Risk.” GovInfoNow, updated August 10, 2026. https://govinfonow.com/recall/49174-heartmate-3-system-controller-recall-backup-battery-failures-risk. Based on FDA recall #Z-2519-2026 (https://api.fda.gov/device/enforcement.json?search=recall_number:%22Z-2519-2026%22&limit=1).

The FDA announced on May 13, 2026, that Thoratec LLC is recalling the HeartMate 3 System Controller due to potential 11 volt backup battery failures. The agency issued recall number Z-2519-2026 for the device distributed worldwide.

How to tell if you have it

  • HeartMate 3 System Controller
  • Model/Catalog Number: 106531US
  • UPC: 05415067039446

The hazard

The recall is due to 11 volt backup battery failures. The HeartMate 3 System Controller acts as the central power and communication hub for the HeartMate 3 LVAS.

Context

GovInfoNow's records show Thoratec LLC has five other recalls on record since June 25, 2024. Recent Thoratec recalls include a CentriMag Blood Pump recall on Oct. 10, 2025, for pumps that may not securely lock into the motor, and a HeartMate II LVAS Implant Kit recall on Oct. 9, 2025, regarding backup battery fault alarms. Other recent recalls of similar products include the Ventec VOCSN+Pro Ventilator recall (May 8, 2026) for backup alarm failures, the Philips Allura Xper FD10C Medical System recall (Dec. 15, 2025) for electrical short-circuit risks, and the Philips Cardiac Workstation 7000 recall (July 1, 2026) for inaccurate heart rate data.

How to tell if you have this one

Check for the model number 106531US on the HeartMate 3 System Controller. The product was sold in the US with specific serial numbers listed in Attachment E.

  • Brand
    HeartMate
  • Product
    Brand Name: HeartMate Product Name: HeartMate 3" System Controller Model/Catalog Number: 106531US Software Version: N/A
  • Category
    Medical device
FDA recall event · 3 products

All 3 products in this recall

FDA lists each product line separately under one recall event. Check your product description, lot or code numbers against each row. Every row shares the hazard and remedy on this page.

  • Classification
    Class II
  • Status
    Ongoing
  • Distribution
    Worldwide - US Nationwide distribution including in the states of AL, AR, AZ, CA, DC, DE, FL, GA, IA, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, NC, NE, NJ, NY, OH, OK, OR, PA, SC, TN, TX, UT, VA, WA, WI and the countries of Canada, Germany, Japan, Netherlands, Poland, Spain.
Recall numberProduct, codes & lotsQuantity
Z-2518-2026Brand Name: HeartMate Product Name: HeartMate 3 Left Ventricular System (LVAS) Kits Model/Catalog Number: 106524US Software Version: N/A Product Description: The HeartMate 3" Left Ventricular Assist System (LVAS) is a set of equipment and materials that together comprise a medical device designed to provide therapeutic benefit to those affected with advanced heart failure. In service, the LVAS assumes some or all of the workload of the left ventricle, thereby restoring the patient's systemic perfusion while palliating the underlying pathology. The LVAS features a Left Ventricular Assist Device (LVAD), a blood pump intended for long-term implantation in such patients, an extracorporeal Controller, plus all of the features, controls, attachments, interfaces, power sources, supporting equipment, labeling, and tools required to achieve the desired therapeutic benefit. Component: No; Lot Code: Model Number: 106524US UDI/GTIN 05415067039323 Serial Numbers Distributed in US: See Attachment E for serial numbers distributed.4
Z-2519-2026Brand Name: HeartMate Product Name: HeartMate 3" System Controller Model/Catalog Number: 106531US Software Version: N/A Product Description: The HeartMate 3" System Controller acts as the central power and communication hub for the HeartMate 3 LVAS. It passes power from the Power Module, the Mobile Power Unit, Lithium-Ion Batteries, or its own integrated emergency backup supply, down to the LVAD via the Driveline. The HeartMate 3 System Controller constantly monitors system performance through communication with the implanted LVAD and Controller internal measurements and alerts the user to any alarm conditions by activating membrane panel LEDs and integrated audio annunciators. Further information on alarm conditions as well as system status can be attained by the user from the front panel LCD on the System Controller. When connected to a HeartMate Touch" Communication System, the System Controller sends information regarding the System Controller and Pump Status once per second to provide additional information to the user. This link also allows the clinician to set new patient operating parameters (e.g. pump speed) and provides a link for downloading trend and/or event recorder data. Component: Yes, HeartMate 3 Left Ventricular System (LVAS) Kits; Lot Code: Model Number:106531US UDI/GTIN: 05415067039446 Serial Numbers Distributed in US: See Attachment E for serial numbers distributed.694
Z-2520-2026Brand Name: HeartMate Product Name: HM 11V Li-ion Backup Battery, ABT Model/Catalog Number: 106128 Software Version: N/A Product Description: The HeartMate 11 Volt Lithium Ion Standalone Backup Battery is a component of the HeartMate 3" System Controller and provides power to the System Controller. The HeartMate System Controller is an external device that manages the HeartMate Left Ventricular Assist System (LVAS), including alarms, system monitoring, and communication. It contains an internal 11V lithium-ion backup battery that provides at least 15 minutes of emergency power should the main system power source fail. The backup battery must be properly installed, charges automatically during normal use, and has a 36-month service life from date of manufacture. Component: Yes, HeartMate 3" System Controller; Lot Code: Model Number: 106128 UDI/GTIN 05415067039880 Serial Numbers Distributed in US: See Attachment E for serial numbers distributed.12
Based on the official FDA remedy

What to do — step by step

  1. Check Controller Model

    Identify the model number on the controller, which should be 106531US for affected units.

  2. Contact Manufacturer

    Reach out to Thoracec LLC for further instructions on the recall remedy.

Where it went and when

Where it was distributed

Distributed nationwide and abroad; the notice names 35 states.

Alaska: nationwideAKMaine: named in the noticeMEVermont: nationwideVTNew Hampshire: nationwideNHWashington: named in the noticeWAIdaho: nationwideIDMontana: nationwideMTNorth Dakota: nationwideNDMinnesota: named in the noticeMNIllinois: named in the noticeILWisconsin: named in the noticeWIMichigan: named in the noticeMINew York: named in the noticeNYRhode Island: nationwideRIMassachusetts: named in the noticeMAOregon: named in the noticeORNevada: nationwideNVWyoming: nationwideWYSouth Dakota: nationwideSDIowa: named in the noticeIAIndiana: named in the noticeINOhio: named in the noticeOHPennsylvania: named in the noticePANew Jersey: named in the noticeNJConnecticut: nationwideCTCalifornia: named in the noticeCAUtah: named in the noticeUTColorado: nationwideCONebraska: named in the noticeNEMissouri: named in the noticeMOKentucky: named in the noticeKYWest Virginia: nationwideWVVirginia: named in the noticeVAMaryland: named in the noticeMDDelaware: named in the noticeDEArizona: named in the noticeAZNew Mexico: nationwideNMKansas: named in the noticeKSArkansas: named in the noticeARTennessee: named in the noticeTNNorth Carolina: named in the noticeNCSouth Carolina: named in the noticeSCDistrict of Columbia: named in the noticeDCOklahoma: named in the noticeOKLouisiana: named in the noticeLAMississippi: named in the noticeMSAlabama: named in the noticeALGeorgia: named in the noticeGAHawaii: nationwideHITexas: named in the noticeTXFlorida: named in the noticeFL

FDA distribution: “Worldwide - US Nationwide distribution including in the states of AL, AR, AZ, CA, DC, DE, FL, GA, IA, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, NC, NE, NJ, NY, OH, OK, OR, PA, SC, TN, TX, UT, VA, WA, WI and the countries of Canada,…” States read from FDA’s own wording; “not listed” means the notice does not name it.

Named in the notice: Alabama, Arizona, Arkansas, California, Delaware, District of Columbia, Florida, Georgia, Illinois, Indiana, Iowa, Kansas, Kentucky, Louisiana, Maine, Maryland, Massachusetts, Michigan, Minnesota, Mississippi, Missouri, Nebraska, New Jersey, New York, North Carolina, Ohio, Oklahoma, Oregon, Pennsylvania, South Carolina, Tennessee, Texas, Utah, Virginia, Washington, Wisconsin.

Recall timeline

FDA published this recall 42 days after the firm started it.

1. Firm started the recall: May 13, 202612. FDA classified it Class II: Jun 18, 202623. Published in FDA’s Enforcement Report: Jun 24, 202632026
  1. Firm started the recall
  2. FDA classified it Class II
  3. Published in FDA’s Enforcement Report

Dates from the agency record only; steps without a date are left out.

Similar recalls

Latest medical device recalls

Keep exploring

Where this comes from

The facts (hazard, remedy, dates, manufacturer) are pulled from the official FDA recall record. The plain-language summary and step-by-step checklist are written by GovInfoNow to make the official notice easier to act on — they don’t replace it.

  • Official source: FDA Recall #Z-2519-2026 (May 13, 2026) — FDA publishes no per-recall page; this is the official machine-readable enforcement record. Search FDA recalls for Z-2519-2026 to see it in context.
  • Plain-language summary written by qwen3:4b on August 10, 2026, from the official record above. Not reviewed by a person — if it conflicts with the FDA notice, the notice is correct. Report an error on this page.
  • GovInfoNow is an independent service and is not a government agency. We republish official FDA recall data; we don’t issue, amend or administer recalls.
GovInfoNow is an independent guide. We are not FDA or any government agency. Always confirm details with the official recall.Data: CPSC · FDA · NHTSA · USDA