Spectrum Medical Recalls Quantum PureFlow Heat Exchangers Due to Leak Risk

Spectrum Medical recalls Quantum PureFlow Standard Heat Exchangers due to a blood-to-glycol leak hazard. Check lot code 18051160302205.

🇺🇸 FDA recall #Z-3327-2026Medical deviceSpectrum Medical ›
✎ GovInfoNow plain-language explainer

Spectrum Medical SRL is recalling the Quantum PureFlow Standard Heat Exchanger because of a potential leak between the blood and glycol circuits. This device is used during cardiopulmonary bypass procedures to heat or cool blood. The specific recalled units have lot code 18051160302205. Read more at govinfonow.com/recall/1449549-spectrum-medical-srl-recalls-brand-name-quantum-pureflow-product-name.

Source Summary by GovInfoNow · govinfonow.com/recall/1449549-spectrum-medical-srl-recalls-brand-name-quantum-pureflow-product-name · Updated October 14, 2026 · FDA enforcement record: FDA #Z-3327-2026

Cite this page

“Spectrum Medical Recalls Quantum PureFlow Heat Exchangers Due to Leak Risk.” GovInfoNow, updated October 14, 2026. https://govinfonow.com/recall/1449549-spectrum-medical-srl-recalls-brand-name-quantum-pureflow-product-name. Based on FDA recall #Z-3327-2026 (https://api.fda.gov/device/enforcement.json?search=recall_number:%22Z-3327-2026%22&limit=1).

The FDA announced on July 17, 2026, that Spectrum Medical SRL is recalling the Quantum PureFlow Standard Heat Exchanger due to a potential blood-to-glycol leak. This voluntary Class II recall affects units distributed nationwide.

How to tell if you have it

  • Brand: Spectrum Medical
  • Product Name: Quantum PureFlow Standard Heat Exchanger High Flow 3/8 W
  • Model/Catalog Number: HX55V-S0W
  • Lot Code: 18051160302205

The hazard

The recall is due to a blood-to-glycol leak in the heat exchanger, according to the FDA. The device is intended for use with compatible Heater/Cooler systems during routine cardiopulmonary bypass procedures.

Context

GovInfoNow's records show Spectrum Medical has been involved in other recent recalls, including a July 6, 2026, recall of Sodium Chloride Injection for infection risk. Other recent recalls of similar products include the June 24, 2026, ICU Medical Hotline Fluid Warming Set Recall and the August 10, 2026, Fresenius Medical Care 5008X HD/HDF with CLiC Blood Tubing Set Recall.

How to tell if you have this one

Look for the Quantum PureFlow Standard Heat Exchanger High Flow 3/8 W with Model/Catalog Number HX55V-S0W. Check the lot code on the packaging; the recalled units have lot code 18051160302205.

  • Brand
    Spectrum Medical
  • Category
    Medical device
FDA recall event · 2 products

All 2 products in this recall

FDA lists each product line separately under one recall event. Check your product description, lot or code numbers against each row. Every row shares the hazard and remedy on this page.

  • Classification
    Class II
  • Status
    Ongoing
  • Distribution
    US Nationwide distribution in the states of AL, CA, FL, KS MA, MD, MI, MO, NC, NJ, NY, OH, OR, PA, SC, TN, TX, VA, WI.
Recall numberProduct, codes & lotsQuantity
Z-3327-2026Brand Name: Quantum PureFlow Product Name: Quantum PureFlow Standard Heat Exchanger High Flow 3/8 W Model/Catalog Number: HX55V-S0W Software Version: N/A Product Description: The Quantum PureFlow Standard Heat Exchanger is intended to be used with a compatible Heater/Cooler system to heat/cool blood during routine cardiopulmonary bypass (CPB) procedures up to 6 hours in duration with a maximum flow rate of 8 l/min. Quantum PureFlow Standard Heat Exchanger is a single use device which allows heating/cooling the blood during extracorporeal circulation. The device is sold sterile in a blister pack in a multiple box of 4 units. Device surfaces in contact with blood are treated with a phosphorylcholine-based biocompatible coating. The device has been designed to be powered by heaters coolers that use water or a glycol-based heat transfer fluid (HTF). Component: N/A; Lot Code: 18051160302205 (HX55V-S0W)9448
Z-3328-2026Brand Name: Quantum PureFlow Product Name: Quantum PureFlow Standard Heat Exchanger High Flow 3/8 Model/Catalog Number: HX55W-S0 Software Version: N/A Product Description: The Quantum PureFlow Standard Heat Exchanger is intended to be used with a compatible Heater/Cooler system to heat/cool blood during routine cardiopulmonary bypass (CPB) procedures up to 6 hours in duration with a maximum flow rate of 8 l/min. Quantum PureFlow Standard Heat Exchanger is a single use device which allows heating/cooling the blood during extracorporeal circulation. The device is sold sterile in a blister pack in a multiple box of 4 units. Device surfaces in contact with blood are treated with a phosphorylcholine-based biocompatible coating. The device has been designed to be powered by heaters coolers that use water or a glycol-based heat transfer fluid (HTF). Component: N/A; Lot Code: 18051160301178 (HX55W-S0)3232
Based on the official FDA remedy

What to do — step by step

  1. Stop Using Recalled Units

    Do not use any Quantum PureFlow Standard Heat Exchangers with lot code 18051160302205.

  2. Contact Manufacturer for Remedy

    The recall record does not specify the current remedy or return instructions; contact Spectrum Medical SRL directly for further guidance.

Where it went and when

Where it was distributed

Distributed nationwide; the notice names 19 states.

Alaska: nationwideAKMaine: nationwideMEVermont: nationwideVTNew Hampshire: nationwideNHWashington: nationwideWAIdaho: nationwideIDMontana: nationwideMTNorth Dakota: nationwideNDMinnesota: nationwideMNIllinois: nationwideILWisconsin: named in the noticeWIMichigan: named in the noticeMINew York: named in the noticeNYRhode Island: nationwideRIMassachusetts: named in the noticeMAOregon: named in the noticeORNevada: nationwideNVWyoming: nationwideWYSouth Dakota: nationwideSDIowa: nationwideIAIndiana: nationwideINOhio: named in the noticeOHPennsylvania: named in the noticePANew Jersey: named in the noticeNJConnecticut: nationwideCTCalifornia: named in the noticeCAUtah: nationwideUTColorado: nationwideCONebraska: nationwideNEMissouri: named in the noticeMOKentucky: nationwideKYWest Virginia: nationwideWVVirginia: named in the noticeVAMaryland: named in the noticeMDDelaware: nationwideDEArizona: nationwideAZNew Mexico: nationwideNMKansas: named in the noticeKSArkansas: nationwideARTennessee: named in the noticeTNNorth Carolina: named in the noticeNCSouth Carolina: named in the noticeSCDistrict of Columbia: nationwideDCOklahoma: nationwideOKLouisiana: nationwideLAMississippi: nationwideMSAlabama: named in the noticeALGeorgia: nationwideGAHawaii: nationwideHITexas: named in the noticeTXFlorida: named in the noticeFL

FDA distribution: “US Nationwide distribution in the states of AL, CA, FL, KS MA, MD, MI, MO, NC, NJ, NY, OH, OR, PA, SC, TN, TX, VA, WI.” States read from FDA’s own wording; “not listed” means the notice does not name it.

Named in the notice: Alabama, California, Florida, Kansas, Maryland, Massachusetts, Michigan, Missouri, New Jersey, New York, North Carolina, Ohio, Oregon, Pennsylvania, South Carolina, Tennessee, Texas, Virginia, Wisconsin.

Recall timeline

FDA published this recall 3 months after the firm started it.

1. Firm started the recall: Jul 17, 202612. FDA classified it Class II: Sep 29, 202623. Published in FDA’s Enforcement Report: Oct 7, 202634. Added to GovInfoNow: Oct 13, 202642026
  1. Firm started the recall
  2. FDA classified it Class II
  3. Published in FDA’s Enforcement Report
  4. Added to GovInfoNow

Dates from the agency record only; steps without a date are left out.

✎ GovInfoNow

Questions people ask

How many units were recalled and where were they sold?

9,448 units were distributed nationwide in the US, specifically in AL, CA, FL, KS, MA, MD, MI, MO, NC, NJ, NY, OH, OR, PA, SC, TN, TX, VA, and WI.

Similar recalls

Latest medical device recalls

Keep exploring

Where this comes from

The facts (hazard, remedy, dates, manufacturer) are pulled from the official FDA recall record. The plain-language summary and step-by-step checklist are written by GovInfoNow to make the official notice easier to act on — they don’t replace it.

  • Official source: FDA Recall #Z-3327-2026 (July 17, 2026) — FDA publishes no per-recall page; this is the official machine-readable enforcement record. Search FDA recalls for Z-3327-2026 to see it in context.
  • Plain-language summary written by qwen3.6:35b-a3b on October 14, 2026, from the official record above. Not reviewed by a person — if it conflicts with the FDA notice, the notice is correct. Report an error on this page.
  • GovInfoNow is an independent service and is not a government agency. We republish official FDA recall data; we don’t issue, amend or administer recalls.
GovInfoNow is an independent guide. We are not FDA or any government agency. Always confirm details with the official recall.Data: CPSC · FDA · NHTSA · USDA