Full Vision recalls specific Trackmaster treadmills due to rare risk of failing to stop during falls when the magnetic safety tether is pulled loose. Affected models include GE T2100-ST2 220V with serial numbers GEDC-6765 to GEDC-6852.
This has been identified a rare occurrence, under a specific scenario, where the circuit is found in a latch-up condition on the PCB that controls the safety function of the Magnetic Safety Tether, that when the magnet is pulled loose as during a fall, the treadmill may fail to stop.
Full Vision is recalling specific Trackmaster treadmills that could fail to stop if a fall occurs, potentially causing injury. This rare issue happens when the magnetic safety tether is pulled loose during a fall, which may not activate the safety mechanism.
The treadmill's safety mechanism may fail to stop if the magnetic tether is pulled loose during a fall. This rare condition occurs when the circuit on the PCB (printed circuit board) controlling the safety function enters a latch-up state.
Treadmill owners with the specific model and serial numbers listed in the recall. Users who run on these treadmills are most at risk during falls.
Check for the model number GE T2100-ST2 220V with serial numbers GEDC-6765 through GEDC-6852. The recall covers specific units sold in China.
Verify your treadmill's model number and serial number against the list provided in the recall notice.
Reach out to Full Vision Inc for guidance on next steps if your treadmill is affected.
Full Vision identified a rare scenario where the treadmill's safety mechanism could fail to stop during a fall, potentially causing injury.
Check for the model number GE T2100-ST2 220V with serial numbers GEDC-6765 through GEDC-6852 as listed in the recall.
Contact Full Vision Inc for guidance on next steps, as the recall does not specify a fix or replacement.
We’ve drafted a message you can send Full Vision to request your refund or repair — edit it as you like.
Subject: Recall Z-0370-2023 — Full Vision Full Vision Hello, I own a Full Vision that is covered by recall Z-0370-2023 from Full Vision. I’m writing to arrange the remedy described in the recall (a refund, repair, or replacement as applicable). Could you please tell me the next steps to resolve this? Thank you.
Experiences, tips, and questions from readers. Every comment is reviewed before it appears.
No comments yet — be the first to share your experience.
The facts (hazard, remedy, dates, manufacturer) are pulled from the official FDA recall record. The plain-language summary and step-by-step checklist are written by GovInfoNow to make the official notice easier to act on — they don’t replace it.