Skip to content

Product Recall Number: 12008

Why was Ecotech EZ® Variable Speed pool pump motors recalled?

The pump cover is not properly grounded posing an electrical shock hazard.

Ecotech EZ® Variable Speed pool pump motors
Here's product recall specific data for Ecotech EZ® Variable Speed pool pump motors.

  • Product Recall Number: 12008

  • Product Safety Warning Number:

  • Date: 2011-10-10

  • Product Safety Warning Date:

  • Name Of Product: Ecotech EZ® Variable Speed pool pump motors

  • Description: The U.S. Consumer Product Safety Commission, in cooperation with the firm named below, today announced a voluntary recall of the following consumer product. Consumers should stop using recalled products immediately unless otherwise instructed. It is illegal to resell or attempt to resell a recalled consumer product.

  • Hazard Description: The pump cover is not properly grounded posing an electrical shock hazard.

  • Consumer Action: None Listed

  • Original Product Safety Warning Announcement: None Listed

  • Remedy Type: Repair

  • Units: Approximately 2,000

  • Incidents: None reported.

  • Remedy: Customers should stop using the recalled pool pumps immediately and call Nidec Motor Corporation to arrange a free repair.

  • Sold At: Pool motor distributors, pool dealers and pump manufacturers nationwide from September 2010 through August 2011 for about $1,000.

  • Importers: None Listed

  • Manufacturers: Nidec Motor Corporation, of St. Louis, Mo. and Emerson Motor Company, a division of Emerson Electric Co., of St. Louis, Mo.

  • Distributors: None Listed

  • Manufactured In: Mexico

  • Custom Label: None Listed

  • Custom Field: None Listed